4. Motion Control Instructions
4-60 DVP-MC operating manual
Master scaling =1, slave scaling = 2, master offset = 0, slave offset = 0
120
360
Master Position
Slave Position
360
When master scaling =1, slave scaling = 2, master offset = 0, slave offset = 0, slave position is
twice that in original cam curve.
Master scaling =1, slave scaling = 0.5, master offset = 0, slave offset = 0
Master Position
Slave Position
30
90
360
360
When master scaling =1, slave scaling = 0.5, master offset = 0, slave offset = 0, slave position
is half of that in original cam curve.