4. Motion Control Instructions
DVP-MC operating manual 4-69
4.5.4. DMC_CamSet
API
Controller
67
MC_CamSet
Set cam
10MC11T
Explanation of the instruction:
The instruction is applied to modify the relevant parameters of the cam.
Explanation of input and output parameter of the instruction:
Parameter
name
Explanation
Data
type
Available
device
Execute
“DMC_CamSet” instruction is executed as “Execute” turns
Off –> On.
BOOL
M,I,Q,
Constant
CamTableID
The corresponding CAM (electronic CAM table) serial no.
in CANopen Builder software. Range: 1~16.
UINT Constant, D
ActiveNewCam
When “ActiveNewCam” is on and “Execute” is on the rising
edge, the revised cam curve is activated.
BOOL
M,I,Q,
Constant
Reserve —— —— ——
Done “Done” is set on after cam parameter setting is completed. BOOL M,Q
Error
“Error” is set on if any error is detected; if “Execute” goes
off from on, “Error” is reset.
BOOL M,Q
ErrorID Error codes. Please refer to section 5.3. UINT D
Note:
1. DVP10MC11T provides 2048 electronic cam key points and the parameter of every key point is set
via 4 registers. The key point register is used to modify electronic cam curve dynamically and its
register value can be revised through communication and program.