4. Motion Control Instruction
4-100 DVP-MC operating manual
4.6.18. CTD
API
Controller
145
CTD
Down counter
10MC11T
Explanation of the instruction:
CTD is used to achieve the function of downcounter.
When EN is on and the loading input LD turns off -> on, the counter writes the preset value of PV into the
current value of EV and the output CTD is reset. Each time the count-down input CD turns off -> on , the
current value of EV is decreased by 1. When EV is decreased to 0, the output CTD turns on and the counter
stops counting.
Explanation of input and output parameter of the instruction:
Parameter
name
Explanation
Data
type
Available
device
EN
The execution condition of this instruction.
“CTU” instruction is executed as “EN” turns on; “CTD”
and “EV” value keep unchanged as “EN” turns off.
BOOL M,I,Q, constant
CD
When the count-down input “CD” turns off -> on, the
current value of the counter is decreased by1.
BOOL M,I,Q, constant
LD
When “LD” turns off -> on, the counter writes the preset
value of “PV” into current value of “EV” and “CTD” is
reset.
BOOL M,I,Q, constant
PV The preset value of the counter. UDINT Constant, D
CTD
When “EN” turns on and the current value of the counter
is decreased to 0, the output bit “CTD” turns on.
BOOL M,Q
EV
The current value of the counter.
When “EN” turns on and the count-down input “CD”
turns off -> on, the current value of the counter is
decreased by 1; as the current value of the counter
decreased to 0, counting is stopped.
UDINT D