4. Motion Control Instruction
4-102 DVP-MC operating manual
4.6.19. CTUD
API
Controller
146
CTUD
Up/down counter
10MC11T
Explanation of the instruction:
CTUD is used to achieve the function of upcounter or downcounter.
As EN is on, R is off and the count-up input CU turns off -> on, the current value EV of the counter is
increased by 1; as the count-down input CD turns off -> on, the current value EV of the counter is decreased
by 1; as the current value of the counter is greater than or equal to the preset value of the counter, CTUD is
on.
As R turns on, the output CTUD is reset and the current value EV of the counter is cleared as 0.
As EV is up to maximum 4294967295 and the countup bit CU turns off -> on, EV gets minimum 0; as EV
reaches minimum 0, the count-down input CD turns on -> off, EV gets maximum 4294967295.
Explanation of input and output parameter of the instruction:
Parameter
name
Explanation
Data
type
Available
device
EN
The execution condition of this instruction.
“CTUD” instruction is executed as “EN” turns on;
“CTUD” and “EV” value keep unchanged as “EN” turns
off.
BOOL M,I,Q, constant
CU
As “CU” turns off -> on, the current value of the counter
is added by 1.
BOOL M,I,Q, constant
CD
When “CD” turns off -> on, the current value of the
counter is reduced by 1.
BOOL M,I,Q, constant
R
When “R” turns on, the current value of the counter is
reset to 0 and output “CTUD” turns off.
BOOL M,I,Q, constant
PV The preset value of the counter. UDINT Constant, D
CTUD
The output bit “CTUD” turns on when the current value
of the counter is greater than or equal to the preset
value of the counter.
BOOL M,Q
EV The current value of the counter. UDINT D