4. Motion Control Instruction
4-110 DVP-MC operating manual
4.6.23. TON_ms
API
Controller
150
TON_ms
On-delay timer
10MC11T
Explanation of the instruction:
TON_ms is an on-delay timer with 1ms as the timing unit.
When EN is on, the input IN is On, the current value ET starts timing from 0 on; as the current value ET is
greater than or equal to the preset value PT, the output TON turns on. After ET reaches PT value, the timing
will not be stopped till ET reaches maximum 4294967295. When the input IN is off, the current value ET of
the timer is cleared as 0 and the output TON is reset. The preset value PT is effective immediately after
being changed.
Explanation of input and output parameter of the instruction:
Parameter
name
Explanation
Data
type
Available
device
EN
The execution condition of this instruction.
“TON_ms” instruction is executed as “EN” turns on; the
output TON and the current value ET keep unchanged
as “EN” turns off.
BOOL M,I,Q, constant
IN
As “IN” is on, the timer starts timing; as “IN” is off, the
current value ET of the timer is cleared as 0 and the
output TON is reset.
BOOL M,I,Q, constant
PT Preset timing value of the timer UDINT Constant,D
TON
“TON” is on as the current value of the timer is greater
than or equal to the preset value PT.
BOOL M,Q
ET The current value of the timer. UDINT D
Note: For the sequence chart of TON_ms, please refer to the program example of TON_s.