4. Motion Control Instruction
4-116 DVP-MC operating manual
4.6.29. MOV
API
Controller
156
MOV
Move 16-bit integer
10MC11T
Explanation of the instruction:
MOV is used for sending the 16-bit integer to the target register.
When EN is On, the content of S will be moved to D without changing the original value in S.
Explanation of input and output parameter of the instruction:
Parameter
name
Explanation
Data
type
Available
device
EN “MOV” is executed as “EN” turns on. BOOL M,I,Q, constant
S The source where the data comes from. INT Constant
D The target register INT D
Note: This instruction is used for moving the 16-bit integer only.
Program example:
When M0 turns Off -> On and keeps in ON status, this instruction will be being executed ever after for
sending the content of register D0 to register D100.
When M0 turns On→Off, this instruction will stop execution.