4. Motion Control Instruction
4-116 DVP-MC operating manual
4.6.29. MOV
API
Controller
156
MOV
Move 16-bit integer
10MC11T
Explanation of the instruction:
MOV is used for sending the 16-bit integer to the target register.
When EN is On, the content of S will be moved to D without changing the original value in S.
Explanation of input and output parameter of the instruction:
Parameter
name
Explanation
Data
type
Available
device
EN “MOV” is executed as “EN” turns on. BOOL M,I,Q, constant
S The source where the data comes from. INT Constant
D The target register INT D
Note: This instruction is used for moving the 16-bit integer only.
Program example:
When M0 turns Off -> On and keeps in ON status, this instruction will be being executed ever after for
sending the content of register D0 to register D100.
When M0 turns OnOff, this instruction will stop execution.