4. Motion Control Instruction
4-140 DVP-MC operating manual
Example 2:
Program Explanation:
When the input pin S of Offset_DI instruction and the output pin D of MOV_DI instruction are linked with
a line, the In_E value is invalid.
When M1 is on, the source index register address of Offset_DI instruction is the input device (S) address
of MOV_DI function block, which is fixed to D300.
The output D of Offset_DI instruction is D800, Out_E= 9, the destination index register address is
D(800+9)=D809.
Move the content of D300 to D809.
When Out_E value changes, the content of D300 can be moved to different registers.
Example 3:
Program Explanation:
The output pin D of Offset_DI instruction and the input pin S of MOV_DI instruction are linked with a line,
the Out_E value is invalid.
When M2 is on, the input S of Offset_DI instruction is D3200, In_E=5555 and the source index register
address is D(3200+5555)=D8755.
The vaule of the source index register address is moved to the output D of MOV_DI instruction and the
D8755 value is moved to D700.
When In_E value changes, the content of different registers can be moved to D700.
Page view 180