2. System Function
DVP-MC operating manual 2-11
Special
D
Function explanation Attribute Data type latched Remark
D6516
Communication ID
and communication
format of
DVP10MC11T
R/W UINT Y
b3~b0=0000: 7,E,1,ASCII
b3~b0=0001: 7,O,1,ASCII
b3~b0=0010: 7,N,1,ASCII
b3~b0=0100: 8,N,2,RTU
b7~b4=0000: 9600bps
b7~b4=0001: 19200bps
b7~b4=0010: 38400bps
b7~b4=0011: 57600bps
b7~b4=0100: 115200bps
b15~b8 are used to set the
modbus node ID, e.g.
b15~b8=00000001which
indicates that modbus node ID
is 1, likewise other modbus
node ID are named in the
same way. Note: b stands for
bit.
D6517
Current scan time for
logical program
Unit: us
R UINT N
The time needed for the
logical program to carry out
scanning currently.
D6518
Max. scan time for
logical program
Unit: us
R UINT N
The maximum time needed for
the logical program to scan
one time.
D6519
Setting of the
quantitiy of D device
in the latched area
R/W UINT Y
The start D device in the
latched area is D7000; the
quantity is specified by D6519;
range: 0~3000.
D6520
Setting of the
quantitiy of M device
in the latched area
R/W UINT Y
The start M device in the
latched area is M3000; the
quantity is specified by D6520;
range: 0~1000
D6527
The pulse number
that servo motor
feeds back to servo
drive
R DINT N
When DMC_ CapturePosition
is used for position capture in
mode 1, the value of D6527 is
the pulse number that servo
motor feeds back to servo
drive.