4. Motion Control Instructions
DVP-MC operating manual 4-167
¾ Defaults
Relative, absolute default: The default mode is absolute mode and could be set via G90/G91.
Plane default: The default plane is XY plane and could be switched via G17/G18/G19.
G0-related default: The velocity, acceleration, deceleration are the maximum velocity, maximum
acceleration, maximum deceleration respectively and can be modified via E, F parameter. E+ and E- in
G code can be input to set the different acceleration and deceleration.
Example: G1 X10000 Y32105.6 E+20000 E-90000
Explanation: When the instruction is executed, the cutter moves at the acceleration of 20000
units/second
2
for speeding up and at the deceleration of 90000 units/second
2
for reducing the speed