Appendix B
DVP-MC operating manual B-13
Abnormality response message data structure:
Data order Name Byte
Byte0 High byte
Byte1
Transaction identifier
Low byte
Byte2 High byte
Byte3
Protocol identifier
Low byte
Byte4 High byte
Byte5
Modbus data length
Low byte
Byte6 Modbus ID Single byte
Byte7 0x80+ function code Single byte
Byte8 Abnormality response code Single byte
Note:
Suppose the number of the bit device where to be written in DVP10MC11T in request message is A (Byte
10, Byte 11), If A is divided by 8 with no remainder, the quotient is B; otherwise, the quotient is B +1. B or
B+1 is the Byte number (Byte12) of bit devices in request message.
The low bitByte 13of the value to be written in the bit device in DVP10MC11T in request message is the
values of the start address (Byte8, Byte9) of bit devices in DVP10MC11T.
¾ Example: To set M0~M7=1000 0001,M8~M15=0001 1000, M16~M19=0110 in DVP10MC11T; the address
of M0 is 0x0800
Request message: “ 00 00 00 00 00 0A 01 0F 08 00 00 14 03 81 18 06”
Response message: “00 00 00 00 00 06 01 0F 08 00 00 14”