Appendix C
C-18 DVP-MC operating manual
Special
D
Modbus
address
HEX
Function Range Type Latched Attribute
D26654 E81E
Axis current state (See
section 4.2
UINT No Read only
D26661 E825 -- No Read only
D26662 E826
Pulse number needed when
servo motor rotates for one
circle.
--
DINT
No Read only
D26663 E827
The allowed error between
the given and feedback pulse
number
-- UINT No Read only
D26667 E82B
Current torque (Rated torque
permillage)
-- INT No Read only
D26668 E82C -- No Read only
D26669 E82D
Current speed (Unit: 0.1
r/min
--
DINT
No Read only
D26670 E82E
Present current (Rated
current permillage)
-- INT No Read only
D26671 E82F -- No Read only
D26672 E830
Custom parameter value
--
DINT
No Read only
D26673 E831
D26674 E832
The phase of the terminal
actuator
0~ modulo REAL No Read only
D26675 E833
D26676 E834
The position of the terminal
actuator
-2147483648
~
2147483647
DINT No Read only
Note: The axis parameters such as Position, Velocity, Torque, Current and User defines parameter
can be read via special D only when they are selected. For the method of selecting the
relevant parameter, see section 2.3.1.