Appendix C
DVP-MC operating manual C-31
Special registers related with axis 16
Special
D
Modbus
address
HEX
Function Range Type Latched Attribute
D28416 EF00 Type0: rotary 1: linear 0-1 UINT No Read only
D28417 EF01 No Read only
D28418 EF02
Modulo -- DINT
No Read only
D28419 EF03
Acceleration and
deceleration type0:T 1: S
2:JERK
0-2 UINT No Read only
D28420 EF04 Numerator of electronic gear 0 - 65535 UINT No Read only
D28421 EF05
Denominator of electronic
gear
0 - 65535 UINT No Read only
D28422 EF06
Software limit0:disable,
1:enable
0-1 UINT No Read only
D28423 EF07 -- No Read only
D28424 EF08
The positive position limit
--
DINT
No Read only
D28425 EF09 -- No Read only
D28426 EF0A
The negative position limit
--
DINT
No Read only
D28427 EF0B
Homing mode; please refer to
appendix D
1-35 UINT No Read only
D28428 EF0C -- No Read only
D28429 EF0D
Homing speed
(Unit: r/min)
--
UDINT
No Read only
D28430 EF0E -- No Read only
D28431 EF0F
Maximum speed
Unit: unit/ second
--
UDINT
No Read only
D28432 EF10 -- No Read only
D28433 EF11
Maximum acceleration
Unit: unit/ second
2
--
UDINT
No Read only
D28434 EF12 -- No Read only
D28435 EF13
Maximum deceleration
Unit: unit/ second
2
--
DINT
No Read only
D28436 EF14 -- No Read only
D28437 EF15
Given positionUnit: pulse
--
DINT
No Read only
D28438 EF16 -- No Read only
D28439 EF17
Given speed
(Unit: pulse/second
--
DINT
No Read only
D28440 EF18 -- No Read only
D28441 EF19
Given acceleration
Pulse/second
2
--
DINT
No Read only
D28442 EF1A -- No Read only
D28443 EF1B
Current position (Unit: pulse)
--
DINT
No Read only
D28444 EF1C -- No Read only
D28445 EF1D
Current position error (Unit:
pulse)
--
DINT
No Read only