4. Motion Control Instructions
DVP-MC operating manual 4-9
Parameter
name
Explanation
Data
type
Available
device
Abort
When this instruction execution is aborted, "Abort" turns
on; when “Execute” is off, "Abort" is reset.
BOOL M,Q
Error
If any error is detected, "Error" turns on; when “Execute” is
off, "Error" is reset.
BOOL M,Q
ErrorID Error code. Please refer to selection 5.3. UINT D
Note:
1. While MC_MoveAbsolute instruction is being executed, “Execute”: rising edge occurs, which does
not impact the execution of the instruction.
2. When the velocity, acceleration and deceleration of the instruction are read and written via
human-computer interface, their value types must be set as Double WordFloating
3. When direction values are different, motion directions of rotary axis are also different as follows.
Suppose the output unit of physical actuator is degree, the motion direction of rotary axis is
explained as below.
Direction: 1 (Positive direction)
Current position: 315
°
Target position: 90
°
Movement angle: 135
°
Direction: -1 (Negative direction)
Current position: 315°
Target position: 90°
Movement angle: 225°
Page view 49