Delta 66-651-1 User Manual Page 19

  • Download
  • Add to my manuals
  • Print
  • Page
    / 26
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 18
19- ENG
A08184
TROUBLESHOOTING
Performing repairs may expose voltage sources, moving
parts or compressed air sources, moving parts or
compressed air sources. Personal injury may occur. Prior to attempting
any repairs, unplug the air compressor and bleed off all air tank air
pressure.
PROBLEM
CAUSE
CORRECTION
Pressure switch does
not shut off motor when
compressor reaches "cut-
out" pressure.
Pressure switch "cut-out"
too high.
Move On/Auto/Off lever
to the "OFF" position, if
the outfit does not shut off
contact a Trained Service
Technician.
Contact a Trained Service
Technician.
Excessive tank
pressure - safety
valve pops off.
Tube fittings are not tight
enough.
Tighten fittings where air
can be heard escaping.
Check fittings with soapy
water solution. Do Not
Overtighten.
Air leaks at
fittings.
Air leaks at
pressure switch
release valve.
Defective pressure switch
release valve.
Contact a Trained Service
Technician.
Air leaks in air
tank or at air
tank welds.
Defective air tank. Air tank must be replaced.
Do not repair the leak.
Do not
drill into,
weld or otherwise modify
air tank or it will weaken.
The tank can rupture or
explode.
Air leaks
between head
and valve plate.
Leaking seal.
Air leaks at or
inside check
valve
Check valve seat damaged. A defective check valve
results in a constant air leak
at the pressure release valve
when there is pressure in the
tank and the compressor
is shut off. Replace check
valve. Refer to the "To
Replace or Clean Check
Valve" in the "Service and
Adjustment" section.
Contact a Trained Service
Technician.
Page view 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 25 26

Comments to this Manuals

No comments