Technical data SOLIVIA 3.0 AP G3 TR
INPUT (DC) AUSTRALIA CHINA INDIA KOREA TAIWAN
Max. recommended PV power 3650 W
P
Nominal power 3300 W
Voltage range 125 ... 540 V 125 ... 540 V 125 ... 540 V 125 ... 500 V 125 ... 540 V
Full power MPP range 150 ... 450 V
Nominal current 11.8 A
Max. current 22.0 A
Stand-by power < 0.2 W
OUTPUT (AC) AUSTRALIA CHINA INDIA KOREA TAIWAN
Max. power
1)
3170 W
Nominal power
3000 W
Nominal voltage 230 V 220 V 230 V 220 V 220 V
Voltage range 210.0 ... 264.0 V 187.0 ... 242.0 V 184.0 ... 264.5 V 193.6 ... 242.0 193.6 ... 253.0 V
Nominal current 13.0 A 13.7 A 13.0 A 13.7 A 13.7 A
Max. current 14.3 A 15.5 A 14.3 A 15.5 A 15.5 A
Nominal frequency 50 Hz 50 Hz 50 Hz 60 Hz 60 Hz
Frequency range 48.0 ... 52.0 Hz 49.5 ... 50.5 Hz 47.3 ... 52.7 Hz 59.3 ... 60.5 Hz 58.0 ... 61.0 Hz
Power factor (cos φ) > 0.99 @ nominal power
Total harmonic distortion (THD) < 5 % @ nominal power
GENERAL SPECIFICATION AUSTRALIA CHINA INDIA KOREA TAIWAN
Model name SOLIVIA 3.0 AP G3 TR
Part number Delta EOE46010259
Max. efficiency 96.0 %
Efficiency EU 94.8 %
Operating temperature -25 ... +70°C
Storage temperature -25 ... +80°C
Humidity 0 ... 98 %
Max. operating altitude 2000 m (above sea level)
MECHANICAL DESIGN AUSTRALIA CHINA INDIA KOREA TAIWAN
Size (L x W x D) 410 x 410 x 180 mm
Weight 21.5 kg
Cooling Free convection
AC connector Wieland RST25i3S
DC connector 4 pairs of Multi-Contact MC4
Communication interfaces 2 Harting RJ45 / RS485
Display LCD; 3 LEDs
STANDARDS / DIRECTIVES AUSTRALIA CHINA INDIA KOREA TAIWAN
Protection degree IP65
Safety class I
Overload behavior Current limitation; power limitation
Anti-islanding protection
AS 4777.2; AS 4777.3;
IEC 60255.5
Yes VDE 0126-1-1 PV 501; KS C 8540 Yes
EMC
AS 4777.1; AS 4777.2;
AS 4777.3; EN 61000-6-2;
IEC / EN 61000-6-3
GB /T 17626; GB 17799
IEC / EN 61000-6-2;
IEC / EN 61000-6-3
IEC 60725;
KS C IEC 61000-4-5;
KS C IEC 61000-6-1;
KS C IEC 61000-6-2;
KS C IEC 61000-6-3;
KS C IEC 61000-6-4
IEC / EN 61000-6-2;
IEC / EN 61000-6-3
Safety
AS/NZS 60950;
AS/NZS 3100; AS 4777.2;
AS 4777.3
CGC/GF001:2009
IEC 62103:2003, EN
50178:1997, IEC 62109-
1:2007, IEC 62109-2:2005
PV 501
IEC 62103:2003, EN
50178:1997, IEC 62109-
1:2007, IEC 62109-2:2005
1) The maximum AC power value indicates the power an inverter might be able to deliver. However, such a maximum AC power may not necessarily be achieved.