3. Remove inner bag filter (J) Fig. 19, in the same
manner.
Fig. 19
J
4. The first stage filter (H) Fig. 18, can be replaced or
cleaned depending on its condition. This filter can be
cleaned in one of two methods: a shop-vac can be used
to remove the dust, or compressed air can be used to
blow the dust out of the filter.
WARNING: COMPRESSED AIR CAN BE
DANGEROUS. FOR OPERATOR SAFETY, DO NOT
EXCEED AN AIR PRESSURE OF 30 PSI OR POINT AIR
NOZZLE TOWARD ANYONE OR AIM AIR NOZZLE AT
YOUR OWN BODY. ALWAYS WEAR SAFETY GLASSES
AND DUST MASK WHEN PERFORMING THIS
PROCEDURE.
5. The inner bag filter (J) Fig. 19, cannot be cleaned; it
is disposable and must be replaced.
6. Install both filters in the reverse order in which they
were removed. NOTE: Make certain the AIR FLOW
ARROW on each filter is pointing inward toward the
rear of the air cleaner, as illustrated in Fig. 19.