Delta AP200 User Manual Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
Use proper extension cords. Make sure your extension cord is in good condition and is a 3-wire extension cord which
has a 3-prong grounding type plug and matching receptacle which will accept the machine’s plug. When using an
extension cord, be sure to use one heavy enough to carry the current of the machine. An undersized cord will cause
a drop in line voltage, resulting in loss of power and overheating. Fig. D, shows the correct gauge to use depending
on the cord length. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.
EXTENSION CORDS
OPERATING INSTRUCTIONS
FOREWORD
The Delta ShopMaster Model AP200 Air Cleaner is specifically designed to quietly circulate and filter non-metallic dust
which is generated throughout the work area. The Air Cleaner is furnished with two filters: a disposable outer filter which
filters out 98% of particles five microns in size; and the secondary filter will capture 85% of dust particles of one micron
in size (one micron = one millionth of a meter). Breathing microscopic particles can be a potential health hazard;
therefore, filtering out microscopic dust particles of the mentioned sizes will make for a cleaner and safer environment.
This Air Cleaner will filter the air in a room measuring 20’ x 20’ x 8’ sixteen times an hour. If desired, multiple units can
be used to filter larger areas.
UNPACKING AND CLEANING
Carefully unpack the machine and all loose items from the shipping container(s). Remove the protective coating from
all unpainted surfaces. This coating may be removed with a soft cloth moistened with kerosene (do not use acetone,
gasoline or lacquer thinner for this purpose). After cleaning, cover the unpainted surfaces with a good quality household
floor paste wax.
NOTICE: THE MANUAL COVER PHOTO ILLUSTRATES THE CURRENT
PRODUCTION MODEL. ALL OTHER ILLUSTRATIONS ARE REPRESENTATIVE
ONLY AND MAY NOT DEPICT THE ACTUAL COLOR, LABELING OR
ACCESSORIES AND MAY BE INTENDED TO ILLUSTRATE TECHNIQUE ONLY.
5
Fig. D
MINIMUM GAUGE EXTENSION CORD
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES
Ampere Total Length Gauge of
Rating Volts of Cord in Feet Extension Cord
0-6 115
up to
25 18 AWG
0-6 115 25-50 16 AWG
0-6 115 50-100 16 AWG
0-6 115 100-150 14 AWG
6-10 115
up to
25 18 AWG
6-10 115 25-50 16 AWG
6-10 115 50-100 14 AWG
6-10 115 100-150 12 AWG
10-12 115
up to
25 16 AWG
10-12 115 25-50 16 AWG
10-12 115 50-100 14 AWG
10-12 115 100-150 12 AWG
12-16 115
up to
25 14 AWG
12-16 115 25-50 12 AWG
12-16 115
GREATER THAN 50 FEET NOT RECOMMENDED
Page view 4
1 2 3 4 5 6 7 8 9 10 11 12

Comments to this Manuals

No comments