Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual Page 137

  • Download
  • Add to my manuals
  • Print
  • Page
    / 186
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 136
Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
4-96
Revision May 2009, 00DE, V0.50
Control
mode
VF VFPG FOCPM
Factory Setting: 84
Settings 0 to 4800rpm
0: disable
ASR P determines Proportional control and associated gain (P). ASR I determines integral
control and associated gain (I).
When integral time is set to 0, it is disabled. Pr.10-17 defines the switch frequency for the
ASR1 (Pr.10-13, Pr.10-14) and ASR2 (Pr.10-15, Pr.10-16).
10-17
10-13
10-14
10-15
10-16
Hz
P
I
10-11
10-12
0Hz
10-20
10-21
When using multi-function input terminals to switch ASR1/ASR2, the diagram will be shown
as follows.
ON
OFF
A
SR 1
0.1 sec
OFF
0.1 sec
ASR 1
ASR 2
Setting multi-function input terminal to 17
(ASR1/ASR2 switch)
10-18
ASR Primary Low Pass Filter Gain
Control
mode
VF VFPG FOCPM
Factory Setting: 0.008
Settings 0.000 to 0.350 sec
It defines the filter time of the ASR command.
When setting to 1, this function is disabled.
10-19
Zero Speed Gain (P)
Control
mode
FOCPM
Factory Setting: 80.00
Settings 0.00 to 655.00%
When Pr.11-00 is set to Bit 7=1, Pr.10-19 is valid.
10-20
Zero Speed/ASR1 Width Adjustment
Page view 136
1 2 ... 132 133 134 135 136 137 138 139 140 141 142 ... 185 186

Comments to this Manuals

No comments