Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
4-20
Revision May 2009, 00DE, V0.50
Group 07 Protection Parameters : The parameter can be set during operation.
Paramete
r
Explanation Settings
Factory
Setting
VF VFPG FOCPM
07.00 Reserved
07.01 Reserved
07.02 DC Brake
Current Level
0~100% 0
07.03 DC Brake Time
during Start-up
0.0~60.0 sec 0.0
07.04 DC Brake Time
during Stopping
0.0~60.0 sec 0.0
07.05 DC Brake
Starting
Frequency
0~4000rpm (0.00~400.0Hz) 0.00
07.06 DC Brake
Proportional Gain
1~500 50
07.07 ~
07.10
Reserved
07.11 Fan Control 0: Fan always ON
1: 1 minute after brushless DC motor
drive stops, fan will be OFF
2: Brushless DC motor drive runs
and fan ON, brushless DC motor
drive stops and fan OFF
3: Fan ON to run when preliminary
heat sink temperature attained
4: Fan OFF
1
07.12 Reserved
07.13 Reserved
07.14 Maximum Torque
Command
0300% 100
07.15 ~
07.18
Reserved
Page view 60