Delta BLD-E1 brushless DC motor drive BLD-E1 Series User Manual Page 62

  • Download
  • Add to my manuals
  • Print
  • Page
    / 186
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 61
Chapter 4 Parameters| BLD-E1 Series
Revision May 2009, 00DE, V0.50 4-21
Parameter Explanation Settings Factory
Setting
VF VFPG FOCPM
07.19 Source of
Torque Offset
0: Disable
1: Analog input (Pr.03-
00)
2: Torque offset setting
(Pr.07-20)
3: Control by external
terminal ( Pr.07-21 to 07-
23)
0
07.20 Torque Offset
Setting
0.0~100.0% 0.0
07.21 High Torque
Offset
0.0~100.0% 30.0
07.22 Mid Torque
Offset
0.0~100.0% 20.0
07.23 Low Torque
Offset
0.0~100.0% 10.0
07.24 Forward Motor
Torque Limit
0300% 200
07.25 Forward
Regenerative
Torque Limit
0300% 200
07.26 Reverse Motor
Torque Limit
0300% 200
07.27 Reverse
Regenerative
Torque Limit
0300% 200
07.28 Emergency
Stop (EF) &
Forced Stop
Selection
0: Coast to stop
1: By deceleration Time 1
2: By deceleration Time 2
3: By deceleration Time 3
4: By deceleration Time 4
5: By Pr.01-31
0
07.29 Time Required
for Decreasing
Torque at Stop
0.000~1.000 sec 0.000
Page view 61
1 2 ... 57 58 59 60 61 62 63 64 65 66 67 ... 185 186

Comments to this Manuals

No comments