Chapter 4 ParametersAT |Troubleshooting}| BLD-E1 Series
4-22
Revision May 2009, 00DE, V0.50
Group 08 PM Parameters : The parameter can be set during operation.
Paramete
r
Explanation Settings
Factory
Setting
VF VFPG FOCPM
08.00 Motor Auto
Tuning
0: No function
1: Only for the unloaded motor, auto
measure the angle between
magnetic pole and PG origin (Pr.
08.09)
2: For PM parameters
3: Auto measure the angle between
magnetic pole and PG origin
(Pr.08-09)
0
08.01 Full-load Current
of Motor
40~120%*00.01 Amps #.##
08.02 Rated power of
Motor
0.00~655.35kW #.##
08.03 Rated speed of
Motor (rpm)
0~65535 200
08.04 Number of Motor
Poles
2~96 10
08.05 Rs of Motor 0.000~65.535Ω #
08.06 Reserved
08.07 Lq of Motor 0.0~6553.5mH #
08.08 Back
Electromotive
Force
0.0~6553.5Vrms #
08.09 Angle between
Magnetic Pole
and PG Origin
0.0~360.0° 360.0
08.10 Magnetic Pole
Re-orientation
0: Disable
1: Enable
0