Delta D1600e User Manual Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 14
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
10- ENG
D27665
1. Check and clean the suction filter
after every 50 hours of use.
2. Check and clean the detergent
filter after every 50 hours of use.
Turn nozzle and pull to remove
from chemical application unit.
Clean filter inside nozzle by
flushing it with water on both
sides.
When performing maintenance, you may be exposed to hot
surfaces, water pressure, or moving parts that can cause
serious injury or death!
Before performing any maintenance or repair, unplug unit from power
source, let motor cool and release all water pressure.
To ensure efficient operation and longer life of your pressure washer, a routine
maintenance schedule should be prepared and followed. If the pressure washer is
used in unusual conditions, such as high-temperatures or dusty conditions, more
frequent maintenance checks will be required.
MAINTENANCE
Figure 9
3. Clean the nozzle at end of wand
with the tool provided. Detach the
wand from the gun and remove
any dirt from the nozzle and rinse.
Figure 11
Figure 10
SHUTTING DOWN YOUR
PRESSURE WASHER
1. Place the ON-OFF switch
in the OFF position.
2. Turn off water supply.
3. Pull trigger on spray gun to relieve
any water pressure in hose or spray
gun.
4. Disconnect water supply hose from
water inlet.
5. Disconnect high pressure hose from
outlet.
Page view 9
1 2 ... 5 6 7 8 9 10 11 12 13 14

Comments to this Manuals

No comments