Delta 28-280 User Manual

Browse online or download User Manual for Circular saws Delta 28-280. 60 Hz 3 Phase AC to Bulk DC Converter

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
60 Hz 3 Phase AC to Bulk DC Converter
(Inherent Harmonic Suppression)
MODEL NUMBER SYSTEM
MAIN OFFICE:
8203 Vineland Avenue, Sun Valley, CA 91352 (818) 504-0644 FAX: (818)768-0395
Visit our website at
www.abbott-tech.com and on-line quote form at [email protected].
AR 60
8203 Vineland Avenue
Sun Valley, CA 91352
Tel. 818-504-0644
Fax. 818-768-0395
Call us toll-free
1-800-367-8200
MIL-STD-1399 compliant
Passive power factor correction
Low parts count for high MTBF up to 500,000 hours (naval
sheltered environment)
Rugged construction, MIL-STD-810 and MIL-S-901 compliant
MIL-STD-167 compliant
Rack mountable
AR60C - 50 - 28 A / RB (R- regulated model; B- battery charger)
COOLING METHOD
A - FORCED-AIR (INTEGRAL FANS)
H - WATER (INTEGRAL HEAT EXCHANGER)
DC OUTPUT VOLTAGE
24
28
280
300
OUTPUT POWER (WATTS) *
10 - 1000W
15 - 1500W
25 - 2500W
35 - 3500W
50 - 5000W
75 - 7500W
100 - 10000W
POWER RATING
Harmonic current limits in MIL-STD-1399 are based upon a percentage of fundamental current at full load. Abbott
models are designed for compliant operation at full rated resistive load. Caution should be exercised when selecting
power rating of model to avoid overspecifying, as a converter operating too far below its rating may draw harmonic
currents in excess of MIL-STD-1399 limits, compared with delivered power.
Last updated July 24, 2002
Abbott Technologies offers three standard types of harmonically corrected bulk converters:
Unregulated with power factor correction and power levels from 1000 Watts to 25,000 Watts;
Regulated with power levels from 1000 Watts to 5000 Watts;
Battery Charger Configuration.
OPERATING TEMPERATURE:
Unregulated Units: -40
o
C to + 85
o
C
Regulated Units or Chargers: -40
o
C to + 70
o
C (no derating)
INPUT PRIMARY:
MODEL FAMILY (60 Hz 3ø INPUT)
AR60A 115V DELTA INPUT
AR60B 240V DELTA INPUT
AR60C 440V DELTA INPUT
115V DELTA Suffix A
240V DELTA Suffix B
440V DELTA Suffix C
ISOLATION:
Input to Output: 2500V
Input to Case: 2500V
Output to Case: 500V
VOLTAGE OUTPUT: 24, 28, 280, 300
Other voltages are available upon
request.
INPUT FREQUENCY: 60HZ, 3 Phase.
Power factor corrected.
RELIABILITY:
COOLING METHODS:
Fan-Cooled - Suffix A (standard case);
Water-Cooled - Suffix H (consult factory for
case dimensions)
MOUNTING PROVISIONS:
Soft-deck mounting is available with regular fans.
Hard-deck, ultra-rugged, mounting is available with heavy
duty fans.
TYPICAL WATER-COOLED MODEL
TYPICAL FORCED-AIR COOLED MODEL
MTBF 500,000 hours in naval sheltered
environment (for non-regulated models)
* For units with output power greater than 10,000 Watts, consult factory.