Delta 1.07 VFD-D D User Manual Page 41

  • Download
  • Add to my manuals
  • Print
  • Page
    / 141
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 40
Chapter 4 Parameter Settings|DD Series
4-17
Paramete
r
Explanation
Settings
Factory
Setting
VF
VFP
SVC
FOC
FOC
52:Password error (PcodE) 0
53:Software error (ccodE) 0
54:Communication time-out (cE1) 0
55: Communication time-out (cE2) 0
56: Communication time-out (cE3) 0
57: Communication time-out (cE4) 0
58 Communication time-out (cE10) 0
59:PU time-out (cP10) 0
60: Brake chopper error (bF) 0
61~67: Reserved 0
68: Door open/close complete signal
error
0
69:Door open time-out (DOT) 0
06.23
Electronic Thermal
Overload Relay Selection
0: Special motor for AC drive
1: Standard motor
2: Disable
2
06.24
Electronic Thermal
Characteristic
30.0~600.0sec 60.0
06.25
Auto Restart After Fault
0~10 0
06.26
Auto Reset Time for Restart
after Fault
0.1~600.0 60.0
06.27
Over-torque Detection
Selection (OT1)
0: disable
1: over-torque detection during constant
speed operation, continue to operate
after detection
2: over-torque detection during constant
speed operation, stop operation after
detection
3: over-torque detection during
operation, continue to operate after
detection
4: over-torque detection during
operation, stop operation after detection
0
06.28
Over-torque Detection Level
(OT1)
10~250% 150
06.29
Over-torque Detection Time
(OT1)
0.0~60.0 sec 0.1
Page view 40