Chapter 4 Parameter Settings|DD Series
4-52
Door Close
Holding Speed
Open Door (REV)
Door Open Limit
0.0%
100.0%
Close Door (FWD)
04.00
Door Open
Speed
by Initial
04.08
Door Open
Acceleration
Time 1
04. 09
Door Open
Deceleration
Time 1
04.03
Door Open High Speed 1
04.05
Door Open
Final Speed
04.01
Door Open Distance
by Ini tial Speed
04.04
Door Open
Final Speedby
B e gi ns
04.06
Door Open
by Holding
Speed Begins
04.07
Door Open
Holding Speed
05.03
Door Close
High Speed 1
D oor Clo s e
Acceleration Time 1
05.05
05.04
05.06
Door Close
by Holding
Speed
Begins
05.07
05.09
05.01
Door Close
Distance by
Ini tial Speed
05.00
Door Close
Ini tial Speed
Do or Close Limit
Door Close
Final Speed
Door Close
Final Speed
Door Close
by Final S peed
B e gi ns
05. 08
Door Close Holding Torque
Control mode VF VFPG SVC FOCPG FOCPM
Factory setting: 20.0
Settings 0.0~100.0% (Drive’s rated current)
Response Time of Door Close Holding Torque
Control mode VF VFPG SVC FOCPG FOCPM
Factory setting: 0.20
Settings 0.01~10.00sec
When the door is in the close complete position, it needs holding torque to keep the door still in complete
position. To prevent motor overload, holding torque should be set within a limit.
Door Close High Speed 2
Control mode VF VFPG SVC FOCPG FOCPM
Factory setting: 30.00
Settings 0.00~120.0Hz
Door Close Acceleration Time 2
Control mode VF VFPG SVC FOCPG FOCPM
Factory setting: 1.0
Settings 0.1~3600sec
Door Close Deceleration Time 2
Control mode VF VFPG SVC FOCPG FOCPM
Factory setting: 1.0
Settings 0.1~3600sec
Door Close Holding Torque Level 2
Control mode VF VFPG SVC FOCPG FOCPM
Factory setting: 0.0
Settings 0.0~150.0% (Ac drive’s rated current)
Door Close Time-out Setting
Control mode VF VFPG SVC FOCPG FOCPM
Factory setting: 0.0
Settings 0.0~180.0sec (0.0sec:Disable)
When the time for door closing is longer than the setting in Pr.05-17, door will re-open.
Holding Time for CD (Close Door)Terminal
Control mode VF VFPG SVC FOCPG FOCPM
Factory setting: 0.0
Settings 0.0~999.9sec (999.9sec is always holding)
This parameter is used to clear the CD terminal signal (door close signal) when door open complete.
During the holding period, AC Motor Drive will still be in RUN status. After holding time, AC Motor Drive