Delta DVPEN01-SL User Manual Page 49

  • Download
  • Add to my manuals
  • Print
  • Page
    / 58
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 48
Ethernet Communication Module DVPEN01-SL
DVP-PLC Operation Manual
47
END
M1013
K100
K1 K1
K100
K100 K1
M2 M1
M1SET
M1
TOP
K28
TOP
TOP
K29
K14
K13
K0
D100 K7
K100 K1TOP K1
SET M2
M1RST
K100 K1
M2
K14 D14
RST M2
RST M2
= D14 K2
= D14 K3
FROM
D100TDR
M1000
Explanations:
The data exchange will be executed every one second.
Write the communication address of the destination PLC in CR#28, and DVPEN01-SL will
automatically detect by the previous setting that No. 1 IP is “192.168.0.4".
Write the data in RTC into CR#29 ~ CR#35.
Write “1” into CR#13 to start the data exchange.
CR#14 = 2 refers to successful exchange. CR#14 = 3 refers to failed exchange.
5. Compile the ladder diagram for PLC_A and download it to PLC_A.
END
M1013
K7D0K49K100FROM
Explanations:
The received data are stored in CR#49 ~ CR#55.
The data received every one second are written into D0 ~ D6.
Page view 48
1 2 ... 44 45 46 47 48 49 50 51 52 53 54 ... 57 58

Comments to this Manuals