INSTRUCTION MANUALPART NO. D25235 029-2Copyright © 2002 Delta MachineryTo learn more about DELTA MACHINERY visit our website at: www.deltamachinery.
10-ENGD252351. Place the air compressor on on asolid, level surface.2. Mark the surface using the holesin the air compressor feet as atemplate.3. Dril
11-ENG D25235GROUNDING INSTRUCTIONSThis product should be connected toa metallic, permanent wiring system,or an equipment-grounding terminalor lead on
12-ENGD25235• Use pipe that is the same size asthe air tank outlet. Piping that istoo small will restrict the flow ofair. • If piping is over 100 feet
13-ENG D25235D25235Description of OperationBecome familiar with these controls before operating the unit.On/Auto/Off Switch: Turn this switchON to pro
14-ENGD25235 14-ENGAir Compressor Pump (not shown): Compressesair into the air tank. Working air is not available untilthe compressor has raised the
15-ENG D25235How to Start1. Turn the On/Auto/Off lever to "AUTO" and allow tank pressure to build.Motor will stop when tank pressure reaches
16-ENGD25235 16-ENGMAINTENANCECustomer ResponsibilitiesBeforeeachuse●●●2Every8hoursEvery40hoursEvery100hoursYearlyEvery160hours●●11- more frequent in
17-ENG D25235D25235Changing1. Remove the oil fill plug (A). 2. Remove the oil drain plug (B) anddrain oil into a suitable container. 3. Replace the oi
18-ENGD25235Air Filter - Inspection andReplacementHot surfaces. Riskof burn.Compressor heads are exposedwhen filter cover is removed.Allow compressor
19-ENG D25235Air Compressor Pump Intakeand Exhaust ValvesOnce a year have a Trained ServiceTechnician check the air compressorpump intake and exhaust
2-ENGD25235SAFETY GUIDELINES - DEFINITIONSIndicates an immi-nently hazardous sit-uation which, if not avoided, willresult in death or serious injury.I
20-ENGD25235SERVICE AND ADJUSTMENTSUnit cycles automat-ically when power ison. When doing Maintenance, youmay be exposed to voltagesources, compressed
21-ENG D25235MotorThis motor has a manual thermaloverload protector. If the motor over-heats for any reason, the overloadprotector will shut off the m
22-ENGD25235TROUBLESHOOTINGPerforming repairs may expose voltage sources, movingparts or compressed air sources, moving parts or com-pressd air source
23-ENG D25235PROBLEMCAUSECORRECTIONCompressor isnot supplyingenough air tooperate acces-sories.Prolonged excessive use ofair.Compressor is not largeen
24-ENGD25235PROBLEMCAUSECORRECTIONMotor will notrun.Fuse blown, circuit breakertripped.1. Check fuse box for blownfuse and replace as nec-essary. Rese
25-ENG D25235PROBLEMCAUSECORRECTIONKnocking Noise.Possible defect in safetyvalve.Operate safety valve manuallyby pulling on ring. If valve stillleaks
26-ENGD25235 26-ENG191518171622392523262728323738124738591110121334624AIR COMPRESSOR DIAGRAM
27-ENG D25235PARTS LISTDESCRIPTIONOutside Belt GuardBeltSet ScrewPulleySelf Tapping Screw 10 x 5/8 (2 required)Speed Nut (2 required)Screw (4 required
28-ENGD25235 28-ENGTorque to20-25 ft.-lbs.Torque to32-33 ft.-lbs.PUMP DIAGRAM
29-ENG D25235Part No.ABP-8226501ABP-5961405ABP-5950057ABP-9053201ABP-4000101ABP-9022003ABP-5940050ABP-9101164ABP-9162030ABP-9004009ABP-9110022ABP-9163
3-ENG D25235IMPORTANT SAFETY INSTRUCTIONSSave these instructionsImproper operation or maintenance of this product could result in serious injury andpr
LIMITED WARRANTYDELTA CORPORATION warrants to the original purchaser that all products covered under this warranty arefree from defects in material an
4-ENGD25235WARNING: Risk of BurstingAir Tank: The following conditions could lead to a weakening of the tank, and resultin a violent tank explosion an
5-ENG D25235HOW TO PREVENT ITWHAT CAN HAPPENWARNING: Risk to BreathingWARNING: Risk of Electrical ShockHOW TO PREVENT ITWHAT CAN HAPPENHAZARDHAZARDYou
6-ENGD25235 6-ENGHOW TO PREVENT ITWHAT CAN HAPPENWARNING: RISK OF BURNSTouching exposed metal such as thecompressor head or outlet tubes, canresult in
7-ENG D25235D25235Review and understand all instructionsand warnings in this manual.Become familiar with the operation andcontrols of the air compress
8-ENGD25235Model No. DLKC6580V2Horsepower Peak 6.5Voltage-Single Phase 240V/60Hz/1PhMinimum Branch Circuit Requirement 30 amps*Fuse Type Time DelayAir
9-ENG D252359-ENG D252359-ENG2. Obtain the drain plug extension(D), from the parts bag.3. Apply thread sealant tape to thethreads of the drain plug