INSTRUCTION MANUALPART NO. D27930 Rev.0Copyright © 2002 Delta MachineryTo learn more about DELTA MACHINERY visit our website at: www.deltamachinery.co
10- ENGD27930Voltage and Circuit ProtectionRefer to the Parts Manual for the voltage and minimum branch circuitrequirements.Certain air compressors ca
11- ENGD27930OPERATIONKnow Your Air CompressorREAD THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATINGYOUR UNIT. Compare the illustrations with your
12- ENGD27930Before Starting Break-in ProcedureSerious damage may result if the following break-ininstructions are not closely followed.This procedur
13- ENGD27930MAINTENANCECustomer ResponsibilitiesDaily or aftereach useBefore each useCheck Safety Valve ●Drain Tank ●To Check Safety ValveIf the safe
14- ENGD27930Before you store the air compressor, make sure you do the following:1. Review the "Maintenance" section on the preceding pages
15- ENGD27930Performing repairs may expose voltage sources, movingparts or compressed air sources, moving parts orcompressed air sources. Personal inj
16- ENGD27930PROBLEMCAUSECORRECTIONIt is normal for "some"pressure drop to occur.If there is an excessiveamount of pressure dropwhen the acc
17- ENGD27930PROBLEMCAUSECORRECTIONMotor will notrun.Check fuse box for blownfuse and replace asnecessary. Reset circuitbreaker. Do not use a fuse orc
LIMITED WARRANTYDELTA MACHINERY warrants to the original purchaser that all products covered under this warranty are freefrom defects in material and
2- ENGD27930SAFETY GUIDELINES - DEFINITIONSIndicates animminently hazardoussituation which, if not avoided, willresult in death or serious injury.Indi
3- ENGD27930IMPORTANT SAFETY INSTRUCTIONSSave these instructionsImproper operation or maintenance of this product could result in serious injury andpr
4- ENGD27930WARNING: Risk of BurstingAir Tank: The following conditions could lead to a weakening of the tank, and resultin a violent tank explosion a
5- ENGD27930HOW TO PREVENT ITWHAT CAN HAPPENWARNING: Risk to BreathingWARNING: Risk of Electrical ShockHOW TO PREVENT ITWHAT CAN HAPPENHAZARDHAZARDYou
6- ENGD27930HOW TO PREVENT ITWHAT CAN HAPPENWARNING: RISK OF BURNSTouching exposed metal such as thecompressor head or outlet tubes, canresult in seri
7- ENGD27930Review and understand all instructionsand warnings in this manual.Become familiar with the operation andcontrols of the air compressor.Kee
8- ENGD27930GLOSSARYBecome familiar with these terms before operating the unit.CFM: Cubic feet per minute.SCFM: Standard cubic feet per minute; a uni
INSTALLATIONLocation of the Air CompressorLocate the air compressor in a clean, dry and well ventilated area. The aircompressor should be located at l