DELTA ELEKTRONIKA BV SM6000
Page 1 - 2 SPECIFICATIONS Rev. Sept. 2012
SM 15-400 SM 30-200 SM 45-140 SM 60-100 SM 70-90 SM 120-50 SM 300-20 SM600-10
Out put
volt age
cur rent
0 - 15 V
0 - 400 A
0 - 30 V
0 - 200 A
0 - 45 V
0 - 140 A
0 - 60 V
0 - 100 A
0 - 70 V
0 - 90 A
0 - 120 V
0 - 50 A
0 - 300 V
0 - 20 A
0-600 V
0-10 A
In put
AC 3 phase, 48 - 62 Hz
for use at 380 V, 400 V, 415 V
nom i nal line - line volt age
Op tion P165
for use at 440 V, 480 V (USA)
(op er ates from 360 V, but at
de rated out put, 5300 W@360 V)
cur rent (400 V / 3 ph, full load)
power fac tor, 100%, 50% load
in ter nal fuses
standby in put power (V
o
=I
o
=0)
standby in put power (V
o
=V
max
)
342 - 457 V
396 - 519 V
10.2 A
0.98, 0.97
15 AT
55 W
110 W
342 - 457 V
396 - 519 V
10 A
0.98, 0.97
15 AT
55 W
110 W
342 - 457 V
396 - 519 V
10.3 A
0.98, 0.97
15 AT
55 W
110 W
342 - 457 V
396 - 519 V
10 A
0.98, 0.97
15 AT
55 W
110 W
342 - 457 V
396 - 519 V
10.4 A
0.98, 0.97
15 AT
55 W
130 W
342 - 457 V
396 - 519 V
9.9 A
0.98, 0.97
15 AT
55 W
130 W
342 - 457 V
396 - 519 V
10 A
0.98, 0.97
15 AT
55 W
120 W
342 - 457 V
396 - 519 V
10 A
0.98, 0.97
15 AT
55 W
130 W
Ef fi ciency
400 V AC, 3 ph in put, full load
87 % 89 % 90 % 89 % 89 % 89 % 89 % 89 %
Reg u la tion
Load 0 - 100% CV
Line 342 - 457 V AC CV
(ex ter nal volt age sense)
2.5 mV
0.2 mV
5 mV
0.5 mV
5 mV
1 mV
5 mV
2 mV
5 mV
2 mV
8 mV
2 mV
15 mV
3 mV
20 mV
4 mV
Load 0 - 100% CC
Line 342 - 457 V AC CC
(in ter nal volt age sense,
af ter warm-up)
24 mA
4 mA
12 mA
2 mA
9 mA
1.5 mA
6 mA
1 mA
5 mA
1 mA
3 mA
0.5 mA
1.2 mA
0.2 mA
1.0 mA
0.2 mA
Rip ple + noise
rms (BW=300 kHz) CV
p-p (BW=20 MHz) CV
rms (BW=300 kHz) CC
p-p (BW=20 MHz) CC
CC-rip ple at full load
0.8 mV
8 mV
100 mA
300 mA
1 mV
8 mV
20 mA
60 mA
1.5 mV
10 mV
8 mA
25 mA
2 mV
10 mV
3 mA
10 mA
2 mV
10 mV
3 mA
10 mA
3 mV
25 mV
(20 mV @
full load)
3 mA
10 mA
5 mV
50 mV
(30 mV @
full load)
2 mA
5 mA
10 mV
100 mV
(80 mV @
full load)
2 mA
5 mA
Temp. coeff., per °C CV
CC
35.10
-6
60.10
-6
Sta bil ity
af ter 1 hr warm-up
dur ing 8 hrs CV
CC
t
amb
= 25 ± 1 °C, V
in
= 400 V AC
in ter nal volt age sens ing for
CC-stab.
5.10
-5
10.10
-5
An a log Pro gram ming
Note: for SM300-20 / SM600-10 see ISO AMP
CV CC
Pro gram ming in puts
in put range
ac cu racy
off set
temp. coeff. off set
in put im ped ance
0 - 5 V
± 0.2%
- 0.1 ... +1.3 mV (on 5V)
10 µV / °C
> 1 MOhm
0 - 5 V
± 0.5%
0 ... +2.2 mV (on 5V)
50 µV / °C
> 1 MOhm
Mon i tor ing out puts
out put range
ac cu racy
off set
temp. coeff. off set
out put im ped ance
0 - 5 V
± 0.2%
- 1... 0 mV (on 5V)
3 µV / °C
2 Ohm / max. 4 mA
0 - 5 V
± 0.5%
- 1.1 ... 0 mV (on 5V)
60 µV / °C
2 Ohm / max. 4 mA
ISO AMP Pro gram ming
op tional for low volt. units up to120V (P154),
stan dard on SM300-20 and SM600-10.
Iso lated an a log pro gram ming, range 0 - 5 V / 200 kOhm or 0 - 10 V / 400 kOhm.
See datasheet ISO AMP on www.DeltaPowerSupplies.com for ac cu racy, off set etc.
Ref er ence volt age
on prog. con nec tor V
ref
TC
5.114 ± 15 mV (Ro = 2 Ohm, max. 4 mA)
20 ppm / °C
+12 V out put V
o
on prog. Con nec tor I
max
R
o
12 V ± 0.2 V
0.2 A
3 Ohm
Page 1 - 2 SPECIFICATIONS Rev. Sept. 2012