Delta 16 SM600 User Manual Page 4

  • Download
  • Add to my manuals
  • Print
  • Page
    / 6
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 3
DELTA ELEKTRONIKA BV SM6000
Page 1 - 4 SPECIFICATIONS Rev. Sept. 2012
EMC Power Sup ply Stan dard
Ge neric Emis sion
Ge neric Im mu nity
EN 61204-3,
Emis sion: res i den tial, light in dus trial en vi ron ment (CISPR22-Class B)
Im mu nity: in dus trial en vi ron ment
EN 61000-6-3, res i den tial, light in dus trial en vi ron ment (EN 55022 B)
EN 61000-6-2, in dus trial en vi ron ment
Op er at ing Tem per a ture at full load
20 to + 50 °C
de rate out put to 75% at 60 °C
Hu mid ity
max. 95% RH, non con dens ing, up to 40 °C
max. 75% RH, non con dens ing, up to 50 °C
Stor age tem per a ture
40 to + 85 °C
Ther mal pro tec tion
Out put shuts down in case of in suf fi cient cool ing
MTBF
500 000 hrs
SM 15-400 SM 30-200 SM 45-140 SM 60-100 SM 70-90 SM 120-50 SM 300-20 SM 600-10
Hold-Up time
V
out
= 100%, I
out
= 100%
V
out
= 85%, I
out
= 100%
V
out
= 100%, I
out
= 50%
@ 400 V AC in put
11 ms
23 ms
33 ms
11 ms
23 ms
28 ms
11 ms
23 ms
27 ms
11 ms
24 ms
28 ms
13 ms
23 ms
30 ms
13 ms
24 ms
32 ms
12 ms
24 ms
28 ms
11 ms
23 ms
27 ms
Turn on de lay
af ter mains switch on
200 ms
In rush cur rent
20 A (elec tronic limit)
Phase loss
Out put shuts down in case of phase loss
Se ries op er a tion
max. to tal volt age
Mas ter / Slave op er a tion
600 V
yes
600 V
yes
600 V
yes
600 V
yes
600 V
yes
600 V
yes
1200 V
yes
1200V
yes
Par al lel op er a tion
Nor mal
Mas ter / Slave op er a tion
no limit
max. 3 units
Re mote sens ing
max. volt age drop per load lead
2 V
Lim its Volt age ad just range
Cur rent ad just range
0 - 102%
0 - 102%
Front panel CV/CC-con trols
res o lu tion
knob op er a tion
screw driver ad just ment
Lock func tion for CV/CC-set tings
Selectable Start-up at 0V / 0A or
at last set tings
an a log po ten ti om eters
1)
10 turns (0.03%)
stan dard
op tional (P001)
no
no
1)
op tional with dig i tal encoders (P220) : spec i fi ca tions
for con trols are sim i lar to SM300-20 and SM600-10.
dig i tal encoders
10 or 64 turns
2)
stan dard
no
yes
yes
2)
vari able pitch de pend ing on
op er a tion speed
Me ters
scale volt age
scale cur rent
ac cu racy read out put
read limit set ting
(d = digit)
3.5 digit
0 - 15.00 V
0 - 400 A
0.5% + 2 d
2% + 2 d
3.5 digit
0 - 30.0 V
0 - 200 A
0.5% + 2 d
2% + 2 d
3.5 digit
0 - 45.0 V
0 - 140.0 A
0.5% + 2 d
2% + 2 d
3.5 digit
0 - 60.0 V
0 - 100.0 A
0.5% + 2 d
2% + 2 d
3.5 digit
0 - 70.0 V
0 - 90.0 A
0.5% + 2 d
2% + 2 d
3.5 digit
0 - 120.0 V
0 - 50.0 A
0.5% + 2 d
2% + 2 d
3.5 digit
0 - 300 V
0 - 20.0 A
0.5% + 2 d
2% + 2 d
3.5 digit
0 - 600 V
0 - 10.0 A
0.5% + 2 d
2% + 2 d
Mount ing
Stack ing of units al lowed, air flow is from left to right.
In put Ter mi nals
Screw Ter mi nals for ca ble 2.5 - 4 mm
2
, 3 phase + earth (no neu tral re quired)
Out put Ter mi nals
M12 bolts M10 bolts M10 bolts M10 bolts M10 bolts M8 bolts M8 bolts M8 bolts
Pro gram ming con nec tor
15 pole D-con nec tor at rear panel (FE MALE)
Cool ing
au dio noise level
air flow
Low noise blower, fan speed adapts to tem per a ture of in ter nal heatsink.
ca. 56 dBA at full load, 25 °C am bi ent tem per a ture, 1 m dis tance
ca. 62 dBA at full load, 50 °C am bi ent tem per a ture, 1 m dis tance
From left to right
En clo sure
de gree of pro tec tion
IP20
Di men sions
be hind front panel: h x w x d
front panel: h x w
177 x 443 x 500 mm
177 x 483 mm (19", 4 U)
Weight
27 kg
Page 1 - 4 SPECIFICATIONS Rev. Sept. 2012
(ES) Equipements Scientifiques SA - Département Tests Energie Mesures - 127 rue de Buzenval BP 26 - 92380 Garches
Tél. 01 47 95 99 45 - Fax. 01 47 01 16 22 - e-mail: [email protected] - Site Web: www.es-france.com
Page view 3
1 2 3 4 5 6

Comments to this Manuals

No comments