z Please parallel connect COM end and GND end of the alarm detector (Provide external
power to the alarm detector).
z Please parallel connect the Ground of the DVR and the ground of the alarm detector.
z Please connect the NC port of the alarm sensor to the DVR alarm input(ALARM)
z Use the same ground with that of DVR if you use external power to the alarm device.
z Use the controllable +12V power to reset the smoke sensor remotely.
Figure 3-7
3.8.3 Alarm Output Port
z Provide power to peripheral alarm device.
z To avoid overloading, please read the following relay parameters sheet carefully.
z For controllable +12V, it can be used to provide power to devices such as reset smoke
sensor.
z RS485 A/B cable is for the A/B cable of the PTZ decoder.
Relay Specification
Model:
JRC-27F
Material of the
touch
Silver
Rated switch capacity 30VDC 2A, 125VAC 1A
Maximum switch power 125VA 160W
Maximum switch voltage 250VAC, 220VDC
Rating
Resistance
Load
Maximum switch currency 1A
Between touches with same
polarity
1000VAC 1minute
Between touches with different
polarity
1000VAC 1minute
Insulation
Between touch and winding 1000VAC 1minute
Surge voltage
Between touches with same
polarity
1500V (10×160us)
Length of open
time
3ms max
Length of close
time
3ms max
Mechanical 50×106 times (3Hz)
Longevity
Electrical 200×103 times (0.5Hz)