Delta 37-360 Instruction Manual Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
12
Fig. 16
Fig. 17
THREE PHASE INSTALLATION
If the motor on your machine is wired for 200, 230 or 460 Volts, Three Phase, proceed as follows when connecting
your machine to an electrical power system.
1. Remove screw (A) Fig. 15, and terminal strip cover
(B).
2. Remove plastic covering (C) Fig. 16, that snaps into
terminal strip.
3. Bring three phase power line through access hole in
bottom of terminal strip box and connect the three power
lines to terminals (D) Fig. 17, and the green ground wire
to ground screw (E).
C
E
D
Fig. 15
A
B
The rotation of the cutterhead must be in a
clockwise direction when viewed from the
left side of the machine; that is, the knives
must be rotating toward the infeed table
from the top. If the cutterhead rotation is
incorrect, disconnect the machine from the
power source and interchange any two of
the three incoming power lines connected to
terminals (D) Fig. 17.