Delta PROFIBUS-DP Module for VFD Series Drives PD-01 User Manual Page 19

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 18
PD-01 PROFIBUS-DP Module
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
16
Fault numbers for "Cannot process request" response
NO. Meaning
0 Illegal Parameter number Parameter does not exist
1
Parameter value cannot
be modified
Parameter is a read-only parameter
or can not change in current state
2
Minimum/maximum not
reached / exceeded
18 Other error
IND
Structure of IND for cyclical communication via PPOs
PKE IND PWE1 PWE2
HIGH LOW HIGH LOW HIGH LOW HIGH LOW
15 14 13 12 11-8 7 0
Para Page selection Not used
2
0
2
3
2
2
2
1
0
Function of Parameter Page Selection
Basic PNU
(B.PNU bit 10-0 of PKE)
Page selection
(P.PNU)
Total PN U
(B.PNU+P.PNU*2000)
0…1999 0 0…1999
0…1999 1 2000…3999
0…1999 2 4000…4999
… …
0…1999 15 30000…31999
NOTE:
In IND, Bit 15 uses a multiplier of 2
0
, so the value of Bit 15 for the access P2000-
P3999 must be set to 1.
Parameter value (PWE) 3rd and 4th word
All parameters in VFD series Drives are 16-bit. A 16-bit parameter value is transferred
in PWE2 (4th word). PWE1 (3rd word) must be set to 0 on the PROFIBUS-DP master
in this case.
Page view 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 35 36

Comments to this Manuals

No comments