Delta D2300B Instruction Manual Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 60
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
15- ENG
D28600
When performing maintenance, you may be exposed to hot
surfaces, water pressure, moving parts, or fire that can cause
serious injury or death!
Before performing any maintenance or repair, disconnect spark plug wire, let
engine cool and release all water pressure. The engine contains flammable
fuel. DO NOT
smoke or work near open flames while performing
maintenance.
To ensure efficient operation and longer life of your pressure washer, a routine
maintenance schedule should be prepared and followed. If the pressure washer is
used in unusual conditions, such as high-temperatures or dusty conditions, more
frequent maintenance checks will be required.
ENGINE
Consult the Engine Owners Manual for the manufacturer's recommendations for
any and all maintenance.
NOZZLE CLEANING
If the nozzle becomes clogged with foreign matter, such as dirt, excessive
pressure may develop. If the nozzle becomes partially clogged or restricted, the
pump pressure will pulsate. Clean the nozzle immediately using the nozzle kit
supplied and the following instructions:
1. Shut off the pressure washer and turn off the water supply.
2. Disconnect spark plug wire to insure the unit will not start while performing
maintenance.
3. Pull trigger on gun handle to relieve any water pressure.
4. Disconnect the wand from the gun.
5. Remove the nozzle from the end of the wand with the 2mm allen wrench
provided as shown.
6. Clean the nozzle using the nozzle cleaner provided or a straightened paper
clip. Insert into the nozzle end and work back and forth until obstruction is re-
moved.
7. Direct water supply into nozzle end to backflush loosened particles for 30
seconds.
8. Reconnect spark plug wire
9. Reassemble the nozzle to the wand. Tighten securely to prevent leaks.
10. Reconnect wand to gun and turn on water supply.
11. Start pressure washer and place wand into high pressure setting to test.
MAINTENANCE
Page view 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 59 60

Comments to this Manuals

No comments