Delta Digital timer User Manual

Browse online or download User Manual for Measuring, testing & control Delta Digital timer. Electronic Timer - Series Staircase

  • Download
  • Add to my manuals
  • Print
  • Page
    / 74
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
GIC
Timers
Time Switches
Counters
Logic Controllers
Supply
Monitoring
Devices
PID Controllers
Page view 0
1 2 3 4 5 6 ... 73 74

Summary of Contents

Page 1

GICTimers Time Switches Counters Logic Controllers Supply Monitoring Devices PID Controllers

Page 2 - Compliant

ORDERING INFORMATIONSupply VariationFrequencyTiming RangesReset TimeAccuracySetting AccuracyRepeat AccuracyContact RatingContact MaterialElectrical Li

Page 3 - CONTENTS PAGE NOS

9ORDERING INFORMATIONSupply VariationFrequencyTiming RangesReset TimeAccuracySetting AccuracyRepeat AccuracyContact RatingContact MaterialElectrical L

Page 4

10Supply VariationFrequencyTiming RangesReset TimeAccuracySetting AccuracyRepeat AccuracyOperating Temperature Storage Temperature LED IndicationModeP

Page 5

11ORDERING INFORMATIONCat. No.G23 DT024- V -off l owe e a240 AC/DC, True De ay (P r Off D l y)Description2 T03GDCat. No.ParametersFunctional Diagr

Page 6

12ORDERING INFORMATIONSupply VariationFrequencyTiming Ranges- 20% to +10%50/60 HzModeParametersCat. No.22LDT0Motor Restart 240 VACPower Consumption (M

Page 7

13MOUNTING DIMENSION (mm)CONNECTION DIAGRAM2A5DT5, 2B5DT5, 2AADT5,23GDT0, 2AODT5, 273DT5,29ODT5, 25ADT52AJDT0, 2AJDT1For - 2A5DT5, 2B5DT5, 2AODT5, 2AS

Page 8

MOUNTING DIMENSION (mm)ORDERING INFORMATIONCONNECTION DIAGRAM6ED 73 T3ED73 T7ED 73 TCat. No.36EDT733EDT737EDT7De c iptis r onParametersFrequencyTiming

Page 9 - 2A5DT5 2AJDT0

• Multi-function, Asymmetrical ON/OFF, and Star-Delta timers • Wide operating voltage range• Front access for frequent change of parameters • Universa

Page 10 - Cat. No

MOUNTING DIMENSION (mm)CONNECTION DIAGRAMFor : 40AFS0For : 40SFS0For : 40MFE0For : 47OFE8, 43OFE8, 46OFE8INSTDLYDFor : 40MFS0TM Electronic Timer - Ser

Page 11

ORDERING INFORMATION- 20% to +10% 50/60 Hz0.1s to 10h (ON & OFF Both)0.1s to 10hN.A.100 ms (max.)± 5% of Full scale± 1%1000 operations/h (Max.)

Page 12

General Industrial Controls Private Limited (GIC), is offering services as a well established manufacturer and exporter of Process Control and

Page 13

MOUNTING DIMENSION (mm)CONNECTION DIAGRAM,INSTANTINSTANTTM Electronic Timer - Series Micon 780TERMINAL TORQUE & CAPACITY (70SDT0)(74SDT0)STAR DELT

Page 14

27B1C3B1Supply VariationFrequency230 VAC- 25% to +15% (of )50/60 HzCat. No.TMElectronic Timer - Series Staircase• Compact 17.5mm wide with 10 opera

Page 15 - Interval Mode Selection

FUNCTIONAL DIAGRAMS FOR 27B1C3B1 & 27C1C3B120TM Electronic Timer - Series StaircaseOn initial signal, the output closes & timing starts for

Page 16 - 7ED 73 T

• Compact 17.5 mm• Multi-voltage, Multi-function(8 or 17) • 3 digit LCD for Preset time and Run time • Option to select Up/Down counting • Tamper proo

Page 17 - 40MFS0 40AFS0 40SFS0

FUNCTIONAL DIAGRAMS FOR V0DDTS1 & V0DDTD1ON DELAY [0]CYCLIC OFF/ON {OFF Start, (Sym, Asym)} [1]CYCLIC ON/OFF {ON start, (Sym, Asym)} [2]IMPULSE O

Page 18

Note: 1. For Power-On operation (P) connect the terminal B1 to A1 permanently.2. If the Signal (S) changes during the Timer Duration (T), it does not

Page 19 - 70MDT0 70ADT0

• Time delay is independent of normal voltage and temperature fluctuations• Black pointer gives clear indication of the time set on the calibrated dia

Page 20 - (70SDT0)

• Time delay is independent of normal voltage & temperature fluctuations• Large knob operating on a linear scale makes time setting easy• Set time

Page 21 - 27B1C3B1

GlossaryDelayed Contacts:A contact in a timer that changes state at the end of time that has been set.Instantaneous Contact:A contact that changes st

Page 22 - =5s =5s=5s

Operating Modes / Functions • Delay on Energisation (ON Delay): • Cyclic Instant (Equal ON/OFF): • Interval Timer: • (Signal)-OFF delay: The set tim

Page 23 - Digital Timer

INDEXCONTENTS PAGE NOS.TM ®

Page 25

GICwww.gicindia.comTIME SWITCHESTime Switch FM Series Digital Time Switch Astronomical Time SwitchAstronomical Time Switch Lighting Automation with

Page 26 - BASE MOUNTING

• Modular construction• Inbuilt over-ride facility• High switching capacity• Tamper proof sealing• Analog & Digital version• Daily/Weekly programm

Page 27 - C B 1

31• Precise time programming for Daily/Weekly/Pulse switching• 25 ON/OFF programs • Weekend exclusion (FRI SAT or SAT SUN) and Weekly OFF programming

Page 28 - Glossary

• Astronomical Time Switch in 35mm size• Latitude/Longitude precise to the minute with time zone • Sunrise/Sunset or Twilight rise/set trigger modes•

Page 29 - Operating Modes / Functions

• Dynamic and accurate control based on astronomical mathematics• Sunrise / Sunset or Twilight rise / set trigger • Yearly programming with Season

Page 30

72.0100.0 C/C90.565.017.068.5DIN RAIL 35mm45.01.MR: -Coil of Contactor 12.MY: -Coil of Contactor 23.MB : - Coil of Contactor 3For: T3DDT0Q1Q3Q2MR MY M

Page 31 - TIME SWITCHES

Cat. No.Parameters19D20B00 (ERT 5) 19D20A00 (ERT 1)19C20C00 Dimension (W x H x D) (in mm)Weight (unpacked)CertificationSupply variationActive phase se

Page 32 - Time Switch FM Series

CONNECTION DIAGRAM• Maximum 5 valid users can access the system remotely, using GSM functionality.• To avoid Remote module's SIM theft, "SIM

Page 33 - Digital Time Switches &

GICwww.gicindia.comHOUR METERS & COUNTERS Hour Meter Series HM 36Hour Meter Series HM 48 Digital Hour Meters Impulse Counter Series CR 26Digital C

Page 35 - Astronomical Time Switches

• Robust design with high degree of accuracy and compact size• Frequency independent for AC applications• Indicates operating time in hours and tenths

Page 36

MOUNTING DIMENSION (mm)Hour Meter Series HM36= 45.00 == 45.00 =1. )R 50 (4XMax. Panel Thickness : 0.029 (0.76) to 0.629 (16.00)0.150 DIA(3.80)0.06 R

Page 37 - , OV settings

Hour Meter Series HM48MOUNTING DIMENSION (mm)ORDERING INFORMATIONVoltageK 5 S 13 110VAC 50Hz4 240VAC 50Hz1 24VAC 50HzMountingF Flush Mou

Page 38

• 6-digit LCD• In-built nonvolatile memory (EEPROM) offering exceptional reliability• Wide range of supply voltage • Remote reset • Available in 3 dif

Page 39 - HOUR METERS & COUNTERS

42Cat. No.ParametersSA41A-356115 VAC Supply Variation 2 WattsPower Consumption (Max.)9,99,999Figure Maximum Read OutSpeed Pulse Width Certification10

Page 40 - Hour Meter Series HM36

43MOUNTING DIMENSION (mm)Impulse Counter Series CR 26Panel cutoutPanel cutoutTo avoid the tampering with the reset button you can seal the counter as

Page 41

ORDERING INFORMATIONDigital CountersMOUNTING DIMENSION (mm)CONNECTION DIAGRAMResetSupply ~/-Supply ~/+Reset1 24 3CountCountTERMINAL DESCRIPTIONPin 1:

Page 42 - Hour Meter Series HM48

GICwww.gicindia.comTM PROGRAMMABLE LOGIC CONTROLLERSProgrammable Logic Controller Series

Page 43 - Digital Hour Meters

MOUNTING DIMENSION (mm)ParametersG7DDT9G8DDT9Cat. No.72.065.0100.0 C/C17.068.590.5DIN RAIL 35mm45.0CONNECTION DIAGRAMC1 C2I1Q1 Q2 Q4Q3I3 I4 I5 I6 I7 I

Page 44 - Impulse Counter Series CR 26

MOUNTING DIMENSION (mm)CONNECTION DIAGRAMG7XDTR4G8XDTR4Cat. No.ParametersIsolation voltageBaud Rate Operating temperature Storage temperature2000 Vrms

Page 45

GICwww.gicindia.comTIMERS Electronic Timer - Series Micon™ 175 Electronic Timer - Series Micon™ 225 Electronic Timer - Series Micon™ 350 Electronic

Page 46 - Digital Counters

Programming:Memory:I/O Extensions:Communication Module:For Industry:For Commercial / Building Sector:Programming can be carried out independently usin

Page 47 - LOGIC CONTROLLERS

SUPPLY MONITORING DEVICESSupply Monitoring Series SM 301 Supply Monitoring Series SM 500Supply Monitoring Series SM 501 Supply Monitoring Series SM

Page 48

• Protects against Phase Loss, Phase Reversal and Phase-Phase Unbalance• No auxillary supply needed• Voltage sensing principle• Designed to meet In

Page 49

Cat. No.ParametersMOUNTING DIMENSION (mm)CONNECTION DIAGRAMORDERING INFORMATIONMD71B9MD71BH MD71BFMD71B9MD71BHMD71BFUV / OV with adjustable 0 to 15 m

Page 50 - APPLICATIONS

Cat. No.ParametersMOUNTING DIMENSION (mm)ORDERING INFORMATIONMG73B9MG73BH MG73BFCONNECTION DIAGRAMPPCat. No.DescriptionMG73BHMG73BFMG73B93 Phase 4 Wir

Page 51 - SUPPLY MONITORING DEVICES

53Cat. No.ParametersSupply Monitoring Series SM 501 MOUNTING DIMENSION (mm)CONNECTION DIAGRAMORDERING INFORMATIONMG53BHMG53BF MG53BIL1 L2 L3SM 5011516

Page 52 - MA51BC MA51BK

Cat. No.ParametersSupply Monitoring Series SM 501 MOUNTING DIMENSION (mm)ORDERING INFORMATIONMB53BMDescriptionCat. No.MB53BM415 VAC, adjustable Asymme

Page 53 - MD71BH MD71BF

Cat. No.MC21B5ParametersSupply Monitoring Series SM 501 MOUNTING DIMENSION (mm)ORDERING INFORMATIONDescriptionCat. No.MC21B5415VAC, 48-62HZ Phase fail

Page 54 - MG73BH MG73BF

Cat. No.ParametersSupply Monitoring Series SM 175 ORDERING INFORMATIONMK21D5MA21DN MD21DFMG21DHDescriptionCat. No.MA21DNMC21D5MD21DFMG21DHMK21D5MG21DF

Page 55 - MG53BF MG53BI

Supply Monitoring Series SM 175 MOUNTING DIMENSION (mm)CONNECTION DIAGRAMTERMINAL TORQUE & CAPACITY 17.5 (+0.5, -0.0)57

Page 56 - 0.5-15 s (adjustable)

MOUNTING DIMENSION (mm)ORDERING INFORMATIONDescriptionCat. No.Enclosure Dimension (W x H x D) (in mm)Weight (unpacked)MountingCertificationFlame Ret

Page 57

Cat. No.ParametersFrequency Monitoring Series PD 225 ORDERING INFORMATIONMI81BJMI91BL• Operable in various auxiliary supply voltage conditions &

Page 58 - MA21DN MD21DF

Frequency Monitoring Series PD 225 SignalFrequencyMonitoringSeries PD 225151816MOUNTING DIMENSION (mm)CONNECTION DIAGRAM62.560.012.510.04.3022.5100.58

Page 59 - 17.5 (+0.5, -0.0)

Cat. No.ParametersPTC Thermistor Relay Series PD 225ORDERING INFORMATION• Monitors and Protects motors with Integrated PTC resistor sensors • Protecti

Page 60

• Thermistor relay combined with protection against Phase sequence fault• LED indications for Healthy, Unhealthy, Sensor Open/Short and Phase Se

Page 61 - Series PD 225

Cat. No.ParametersORDERING INFORMATION17A122CB017B122AA0MOUNTING DIMENSION (mm)CONNECTION DIAGRAMRedBlueGreenWhiteRedBlueGreenWhiteControl PowerStopSt

Page 62

17G514FF1 17G614FF1 17G544FF1 17G644FF1 17H5NNHL317H5NNIL317H5NNJL317H6NNHL317H6NNIL317H6NNJL3 110-240V AC, Current Range 60 mA - 300 mA, 1 C/O110-240

Page 63 - Phase Sequence Series PD 225

ENL1L2 L3C1C2B1B2********L /L1N/L2C1C2B1B2151618Y1Y2L /L1N/L2**REMOTE TEST / RESETFAIL- SAFE LATCH VAUX151618151618MCCB151618CONTACTORN/L2L /L1N/L2L

Page 64 - 17C112EB0 17D112DA0

17G715GF2 17G715KF2 17G745GF2 17G745KF2 110-240V AC, Current Range 30 mA - 30 mA, 1 C/O + 1 NO, Manual Reset110-240V AC, Current Range 220-415V AC, Cu

Page 65 - 17G644FF1 17G614FF1

CONNECTION DIAGRAMEarth Leakage Relay Series CMR66MOUNTING DIMENSIONSTERMINAL TORQUE & CAPACITY Use Cu Wire of 60/75°C only.0.54 N.m (5 Lb.in)Term

Page 66 - FAIL- SAFE LATCH

GICwww.gicindia.comTEMPERATURE CONTROLLERS PID Temperature Controller Series PR 69

Page 67 - 17G715KF2 17G745KF2

1CMDT0Supply VariationFrequency12 - 240 VAC/DC- 15% to +10% (of )50/60 HzCat. No.TM Electronic Timer - Series Micon 175• Compact 17.5mm• Wide time

Page 68 - DIN RAIL 35mm

68Cat. No.ParametersPID Temperature Controller Series PR 69151D12B151A12B151B12B 151C12B• Universal Input • Configurable output combination • Field co

Page 69 - TEMPERATURE CONTROLLERS

69Cat. No.Parameters151D13B1151A13B1151B13B1 151C13B1O0 to + 50 COCSupply VariationOperating TemperatureTemperature sensors / inputs Measurement Rang

Page 70 - 151B12B 151C12B

CONNECTION DIAGRAM151A13B1151A12B151B12B151B13B1151C12B151D12B151D13B1151C13B1PID Temperature Controller Series PR 6970

Page 72

GICT-107, M.I.D.C., Bhosari, Pune 411026 (INDIA) Tel: +91 20 30680018 / 30680019 Fax: +91 20 27122574 Email: [email protected] | www.gicindia

Page 73

FUNCTIONAL DIAGRAMS FOR 1CMDT0 & 1CMDTBON DELAY [tn]R U T TTiming commences when supply is present.R energizes at the end of the timing period. CY

Page 74 -

7*Note: Product with test voltage between input and output at 1.5 kVORDERING INFORMATIONCat. No.DescriptionSupply VariationFrequencyTiming RangesReset

Comments to this Manuals