Operating Modes / Functions
Delay on Energisation (ON Delay):
Cyclic Instant (Equal ON/OFF):
• Interval Timer:
(Signal)-OFF delay:
The set time (Delay) starts
when the timer receives supply. The output relay energises at the
end of the pre-set time
On energisation, relay output
switches ON and OFF repeatedly for the set time. Cycle starts
with relay in energised condition. When supply is ,
the relay is reset.
On energisation of Timer, Output relay changes
the state for the time set. After completion of set time, output
relay de-energises. By switching off the supply, the Timer gets
de-energised & is ready for the next cycle of operation.
Timer is energised and relay is in OFF
condition. When control input is given through control contacts,
relay is energised. Delay period commences when control input
is removed. At the end of set time, relay is de-energised and load
is disconnected.
switched OFF
INST. RELAY
ON DELAY
CYCLIC
INTERVAL
OFF DELAY
RELAY
T
RELAY
RELAY
CONTROL
SIGNAL
RELAY
T
T
T
T
MULTIFUNCTIONAL
ON Delay (Retentive): The set time (Delay) starts when timer
receives supply. The output relay energises at the end of the pre-
set time. If power fails during set time, the elapsed time will
retained by timer. Upon resumption of power, remaining cycle
will continue.
ON DELAY
(RETENTIVE/NO VOLT)
Relay
MODE FUNCTION
t1
<
< <
<
t2
<
<
t3
<
<
T
T= t1 + t2 + t3
Asymmetrical ON/OFF (Cyclic Instant): ON/OFF, can be
independently selected from 0.1 Sec. to 10 Hrs. On energisation,
relay output switches on and off repeatedly for the respective set
times. Cycle starts with relay in energised condition. By
removing supply, the relay is reset.
ASYMMETRICAL
ON/OFF
Relay R1, R2 Ton DLY
Toff
Relay R2 INST
Star - Delta: The timer has a fixed transition time from Star to
Delta connection. On energisation, the output star relay energises
instantly. After completion of preset delay time, output Delta
relay energises after fixed pause time. This pause time (60, 90,
120, 150 ) provides the shortest possible 'current off'
pause and simultaneously ensures smooth change over.
±20 ms
STAR - DELTA
Relay
T Tp
Pause TimeSet Time
27
True OFF Delay: On energisation the Relay O/P is in ON Position.
Timing delay period commences when supply to the True OFF
Delay Timer goes OFF. The O/P Relay de-energises at the end of
pre-set time.
TRUE OFF DELAY
Relay
T
MODE FUNCTION
(POWER OFF DELAY)
Relay