Delta Digital timer User Manual Page 35

  • Download
  • Add to my manuals
  • Print
  • Page
    / 74
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 34
• Dynamic and accurate control based on
astronomical mathematics
• Sunrise / Sunset or Twilight rise / set trigger
Yearly programming with Season mode,
DST, Offset, Off hours, Weekly Off enabled
• Protection against under voltage and over voltage
Alternate Mode with Auto load changeover feature
• Three independent channel outputs
ORDERING INFORMATION
Cat. No.
T2DDT0
T3DDT0
Supply Variation
Power Consumption (Max.)
Storage Temperature
-10°C to + 60°C
110-240 VAC, 50/60Hz
110-240 VAC (P-N)3 Phase 4 wire , 50/60Hz
T2DDT0
T3DDT0
TGDDT6
GFDNN3M
GFDNN2S
GFDNN1
110-240 VAC, 2 NO (SPST)
110-240 VAC, 3 Phase 4 wire (P-N), 3 NO (SPST)
Windows based application software for Astro
Memory card
Serial interface cable
USB interface cable
1 Phase,
Description
Cat. No.
Parameters
Q1-A
Q3-A
26-10-09
11:45
Q2-A
MON
ESC
Screen No. 1
DD/MM/YY
26/10/09
HH : MM
11 : 45
Screen No. 2
TIME & DAY SETTING :
1) Power ON the Astro. The screen No.1 will appear.
2) Press ESC key.
3) Set the cursor on "SETTINGS" with help of Z keys and press OK.
4) Set the cursor on "CLOCK" with help of Z keys and press OK.
5) Set the cursor on "DATE / TIME" with help of Z keys and press OK. Then screen No.2 will appear.
6) Press Z1 or Z3 key to locate the cursor at "DAY" parameter position. Then press "ALT" key to edit
the value of Day. When user presses this key, the upper digit of the Day parameter start blinking as
to show it is selected. Press Z2 or Z4 key to increment or decrement the value of digit under edit.
Press Z1 or Z3 key to select next digit of the parameter. Now again press Z2 or Z4 key to increment
or decrement the value of digit. If required value of the Day has edited then press OK key to set it &
come on the screen No. 1 by pressing the ESC key.
7) Similarly select other individual parameters and modify them as per your requirement &
save it as per the above given process.
LONGITUDE
E 000' - 00'
LATITUDE
N 00' - 00'
Screen No. 3
LATITUDE & LONGITUDE :
1) Go to menu by pressing "ESC" key
2) Set the cursor on "SETTINGS" with help of Z keys and press OK
3) Go to "LAT/LONG" using Z2 Key. Then screen No. 3 will appear.
The cursor blinks at E. Press ALT Key to go into edit mode.
Change the direction using Z2 or Z4 key once the required direction is set press ALT to set the
direction. Jump to next character using either Z1 or Z3 key.
Press ALT again to enter into edit mode When user presses this key, the digit starts blinking.
Press Z2 ro Z4 key to increment or decrement the value of digit under edit.
Press Z1or Z3 key to select next digit of the parameter.
Now again press Z2 or Z4 key to increment or decrement the value of digit.
If the required value of latitude longitude has been edited then press OK key to save it.
4) Go to "CLOCK" and Press OK.
5) Select "TIME ZONE" and Press OK. Then screen No.4 will appear.
6) In the screen No. 4, edit sign, hour & minute as per your requirement. Then press OK to save
the changes & & come on the screen No. 1 by pressing the ESC key.
TIME ZONE :
GMT + 00 : 00
Screen No. 4
Astronomical Time Switches
TM
Dimensions (W x H x D) (in mm)
Clock deviation
DST
Mounting
Switching contacts
Shortest switching time (daily)
Power reserve (for clock only)
Base / DIN rail
72 X 90 X 67
2 NO, 8A (resistive load) @ 240 VAC and
5A (resistive load) @ 30 VDC
1min (1 s for pulse)
Certification
Weight (unpacked)
190 g
208 g
EMI/ EMC
Radio Interference Suppression
ESD
Electrical Fast Transients
Surges
Voltage Dips & Interruptions
± 1 s per day over the operating temperature range
settable
1000 h
Operating Temperature -10°C to + 50°C
-20% to +15%
8VA @ 300 VAC
3 NO, 8A( resistive load) @ 240 VAC and
5A (resistive load) @ 30 VDC
Electrical Life
Mechanical Life
5
10
7
10
Degree of Protection IP 20 for Terminals, IP 40 for Enclosure
Pollution Degree II
Supply Voltage ( )
CISPR 14-1
IEC 61000-4-2
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-11
Ed. 5.0 (2005-11) Class A
Ed. 1.2 (2001-04) Level II
Ed. 2.0 (2004-07) Level IV
Ed. 2.0 (2005-11) Level IV
Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)
Display
Under / Over Voltage Trip Level N. A.
N. A.
N. A.
Settable UV: 0 - 220 V & OV: 130 - 330 V
Backlit LC Graphics display for diagnostic view
Trip time for Under / Over Voltage
5 - 16 Sec.
Recovery time
1 - 4 Sec.
Active Phase selection
• Manual override facility
• Single phase and three phase versions
• Modbus Communication
• User friendly software for device configuration
(of )
RoHS
Compliant
33
Page view 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 73 74

Comments to this Manuals

No comments