Delta Digital timer User Manual Page 37

  • Download
  • Add to my manuals
  • Print
  • Page
    / 74
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 36
Cat. No.
Parameters
19D20B00 (ERT 5) 19D20A00 (ERT 1)
19C20C00
Dimension (W x H x D) (in mm)
Weight (unpacked)
Certification
Supply variation
Active phase selection
Operating Temperature
GSM Type
GPRS packet data
AT command set
Suitability
SMS type functionality
SIM Holder
Antenna
Antenna Impedance
Energy Measurement
Energy Measurement Accuracy
Current sensing range
CT ratio
LED Indications
Pulse Out rate
Auxiliary Output
General Port Connectivity
Mounting
Enclosure
Colour
110-240 VAC, 50/60 Hz
-30%, +25%
Yes
Yes
o
-15 to + 60 C
o
C
Dual band 900 / 1800 GSM
Class 10 coding scheme
N. A.
Data Call through GSM, SMS
Text, Cell Broadcast
Connected with the product
50
GSM 7.05 & 7.07
N. A.
Yes No
Class 0.5
N. A.
5A 1A N. A.
N. A.
N. A.
N. A.
Settable up to 40
Tx, Rx, Network, Power, Pulse Out Tx, Rx, Network, Power, SIM Status
3200 pulses / kWh
12 V DC, 200 mA
TTL port for connecting Time-switch
(Astro) USB through USB interface
cable GFDNN1, RS232 through
serial interface GFDNN2S, RS485
through TTL-RS485 converter
G7XDTR4"
DIN / Base
4 Modular
RAL 7016
EMI/ EMC
Harmonic Current Emission
ESD
Radiated Susceptibility
Electrical Fast Transients
Surge
Conducted Susceptibility
Voltage Dips and Interruptions
Radiated Emission
IEC 61000-3-2 Ed. 3.0 (2005-11) Class A
IEC 61000-4-2 Ed. 1.2 (2001-04)
IEC 61000-4-3 Ed. 3.0 (2006-02) Level III
IEC 61000-4-4 Ed. 2.0 (2004-07)
IEC 61000-4-5 Ed. 2.0 Level IV
IEC 61000-4-6 Ed. 2.2 (2006-05) Level III
IEC 61000-4-11 Ed. 2.0 (2004-03) All seven levels
( )
CISPR 14-1 Ed. 5.0 2005-11 Class A
Level II
Level IV
(2005-11)
Note:
1. ERT5 & ERT1 can measure maximum 5A & 1A current respectively.
2. Maximum current measurement limit for ERT-5 is 200A & for ERT-1 it is 40A.
Ex: 1. For CT selection if current required to be measured is upto 200A then CT of 200:5 A ( CT ratio 40) needs to be used.
2. For CT selection if current required to be measured is upto 40A then CT of 40:1 A ( CT ratio 40) needs to be used.
ORDERING INFORMATION
Description
Cat. No.
T3DDT0
19D2000C
19D20B00
19D20A00
19C20C00
19A1000B
TGDDT6
Astro time switch, 110-240 VAC 50/60Hz, 3 NO (SPST)
Surge Suppressor
Astro GSM Module (GSM-ERT5), Remote Side
GSM Module (GSM-ERT1), Remote Side
GSM Module (GSM-RT), PC side
Communication Cable (TTL-TTL) between Astro & GSM Module
Windows based application software for Astro
3 Phase 4 wire (P-N),
Astro
Astro
110-240 VAC (P-N), 3 Phase 4 wire 50/60Hz
• Most of the "ASTRO" parameters can be set remotely using SMS queries. I.e. Output mode, Offset Hrs etc, UV, OV settings.
• Relay Output can be override remotely using SMS query.
• Energy Meter Functionality. Parameter like Load current, Supply voltage, Power, Energy can be known remotely.
• With the help of "Auto Error Code Update" following onsite error can be know remotely during output event.
- Under Voltage
- Over Voltage
- Over Current
- Output actuator short.
- Load Open
72 X 90 X 67
190 g
Lighting Automation with using GSM Technology
TM
Supply Voltage ( )
(of )
RoHS
Compliant
35
Page view 36
1 2 ... 32 33 34 35 36 37 38 39 40 41 42 ... 73 74

Comments to this Manuals

No comments