Frequency Monitoring Series PD 225
ORDERING INFORMATION
MI81BJ
MI91BL
• Operable in various auxiliary supply voltage conditions &
frequency range by selecting proper model
• Models for Over Frequency and
Under/Over Frequency Monitoring
• Monitors frequency of three signals - Sine, Square & Triangular
• Model for Frequency Limit Control: 5 Hz to 135 Hz
• Wide Signal Input Voltage: 15 to 500 VAC
Cat. No.
MI81BJ
MI91BJ
MI81BL
MI91BL
Description
110-240 V AC, Over Frequency Monitoring Series PD 225 with
ON Delay of 500 ms (Fixed), & OFF Delay of 500 ms (Fixed), 1 C/O
220-440 V AC, Over Frequency Monitoring Series PD 225 with
ON Delay of 500 ms (Fixed), & OFF Delay of 500 ms (Fixed), 1 C/O
110-240 V AC, Under/Over Frequency Monitoring Series PD 225 with
ON Delay of 500 ms (Fixed) & OFF Delay of 500 ms to 5 Sec. (Selectable), 1 C/O
220-440 V AC, Under/Over Monitoring Series PD 225 with
ON Delay of 500 ms (Fixed) & OFF Delay of 500 ms to 5 Sec. (Selectable), 1 C/O
Frequency
110-240 VAC, 48-62 Hz
3 VA
o o
- 20 C to + 80 C
95% (Rh)
Base / DIN rail
Power Consumption (Max.)
~ 150 ms
Relay Ouput
Mechanical Life
Electrical Life
Contact Material
Operating Temperature
Storage Temperature
Humidity (Non Condensing)
LED Indications for Relay
Degree of Protection
Dimension (W x H x D) (in mm)
Weight (unpacked)
Mounting
Certification
Supply Variation
-15% to + 15%
Trip Level
Trip Levels
For Signal
Frequency (%)
6A (Resistive) @ 240 VAC / 28 VDC
6
3 x 10
5
1 x 10
Ag alloy
Red LED Flashing if No Signal
22.5 X 83 X 100.5
120 g
Utilization Category
AC - 15
DC - 13
Rated Voltage (Ue): 120/240 V, Rated Current (Ie): 3.0/1.5 A
Rated Voltage (Ue): 24/125/250 V, Rated Current (Ie): 2.0/0.22/0.1 A
0.33 to 1 of Full Scale
1.5 % of Full Scale selected
± 5%
± 0.02%
~ 500 ms
~ 500 ms
Response
Time
220-440 VAC, 48-62 Hz
Over Frequency
Under Frequency
N A
Reset Hysteresis
Setting Accuracy
Repeat Accuracy
ON Delay
OFF Delay
Reset Time
500 ms - 5 s
Signal Type Sinusoidal, Square, Triangular
Signal Input Voltage Range (15 to 500) V
Overall Frequency Range
Frequency Range Selection
(+ 1 to + 10) Hz
(- 1 to - 10) Hz
(40 to 70) Hz
50 Hz
60 Hz
Contact Rating
1 C/O (SPDT)
N. A.
LED Indications for UF & OF N. A.
Seperate Indications given for UF & OF Status
EMI/ EMC
Radio Interference Suppression
ESD
Electrical Fast Transients
Surges
Voltage Dips, Interruptions
Isolation
Adjustable Relay status in healthy or
unhealthy condition using DIP switch "ET"
(Energize to Trip) or "DT" (De-energize to trip.)
• Ease of Frequency setting with
simple Addition & Subtraction
• LED indications for healthy,
unhealthy & no signal conditions
( 5 to 135) Hz
A
0
1
0
1
B
0
0
1
1
Frequency Range
(5 to 15) Hz
(15 to 45) Hz
(45 to 135) Hz
N A
58
Supply Voltage ( )
IP 20 for Terminal, IP 40 for Enclosure
CISPR 14-1
IEC 61000-4-2
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-11
Test voltage between input & output - IEC 60255-5, 2kV
Ed. 5.0 (2005-11) Class A
Ed. 1.2 (2001-04) Level II
Ed. 2.0 (2004-07) Level IV
Ed. 2.0 (2005-11) Level IV
Ed. 2.0 (2004-03) All 7 Levels (AC), IEC 61000-4-29 Ed. 1.0 (2000-08) All 5 Levels (DC)
(of )
o o
- 15 C to + 60 C
RoHS
Compliant
Note: UL Approval for Cat Nos. MI81BL & MI91BL only