Delta 4Ax-602804-xHxx User Manual Page 22

  • Download
  • Add to my manuals
  • Print
  • Page
    / 35
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 21
MACRO-CPU Hardware Reference
HARDWARE RE-INITIALIZATION
MACRO hardware reinitialization to factory defaults is enabled when the SW1 setting is set to 15 or F
(hexidecimal) and the power is cycled at the MACRO Station. The only time the user would want to use a
hardware reinitialization to factory defaults with the MACRO Station would be if the MACRO Station always
powers up with a watchdog (typically if the ring clock at the Ultralite is different than the ring clock at the
MACRO Station). Node 11 will be the only MACRO Station node enabled. Therefore the user will have to enable
node 11 of the MACRO IC at the Ultralite to communicate to the MACRO Station.
Ultralite Example: Servo nodes 0,1,4,5 enabled at Ultralite (I996=$0F8033)
(A) The user would have to enable node 11, I996=$0F8833
(B) Then user can reistablish communications with MS11,(MIvar) commands
(C) Issue MS$$$***11 to ensure re-initialization
(D) Issue MSSAVE11 command to save the factory defaults to the Station
Turbo Ultralite Example: Servo nodes 0,1,4,5 enabled at Ultralite (I6841=$0F8033)
(A) The user would have to enable node 11, I996=$0F8833
(B) Then user can reistablish communications with MS11,(MIvar) commands
(C) Issue MS$$$***11 to ensure re-initialization
(D) Issue MSSAVE11 command to save the factory defaults to the Station
Hardware Re-initialization
18
Page view 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 34 35

Comments to this Manuals

No comments