9.2 Error Message & Trouble Shooting
Table 9-2 Error message
ERROR
Message Possible cause Action
E01: Grid Freq
Over Rating
1. Actual utility frequency is
over the OFR setting
2. Incorrect country setting
3. Detection circuit malfunction
1. Check the utility frequency on the inverter
terminal
2. Check country setting
3. Check the detection circuit inside the
inverter
E02: Grid Freq
Under Rating
1. Actual utility frequency is
under the UFR setting
2. Incorrect country or Grid
setting
3. Detection circuit malfunction
1. Check the utility frequency on the inverter
terminal
2. Check country & Grid setting
3. Check the detection circuit inside the
inverter
E07:Grid
Quality
Non-linear load in Grid and
near to inverter
Grid connection of inverter need to be far
away from non-linear load if necessary
E09: No Grid
1. AC breaker is OFF
2. Disconnect in AC plug
3. Internal fuses are broken
1. Switch on AC breaker
2. Check the connection in AC plug and
make sure it connects to inverter
3. Replace fuses and check all switching
devices in boost & inverter stages
E10: Grid Volt
Under Rating
1. Actual utility voltage is under
the UVR setting
2. Utility voltage is under the
Slow UVR setting during
operation
3. Incorrect country or Grid
setting
4. Detection circuit malfunction
1.&2. Check the utility voltage connection to
the inverter terminal.
3. Check country & Grid setting
4. Check the detection circuit inside the
inverter
E11: Grid Volt
Over Rating
1. Actual utility voltage is over
the OVR setting
2. Utility voltage is over the
Slow OVR setting during
operation
3. Incorrect country or Grid
1.&2. Check the utility voltage o
n the inverter
terminal
3. Check country & Grid setting