23Operation and installation manual SOLIVIA 3.3 AP G3 TR
LED STATUS OPERATIONAL STATE EXPLANATION
green: <off>
red: <off>
yellow: <off>
Night disconnection.
The input voltage (UPV) is lower than
100 V. The solar inverter is not feeding
power to the grid.
green: <on>
red: <on>
yellow: <on>
Initialization
Input voltages: UPV: 100 V to 150 V (self
test ongoing).
green: <ashes>
red: <off>
yellow: <off>
Input- and grid monitoring. Starting conditions are tested.
green: <on>
red: <off>
yellow: <off>
Feed-in operation.
Normal operational state: UPV: 150 V to
450 V.
green: <off>
red: <on/off>
yellow: <on/off>
Equipment fault.
Internal or external fault (interrupted
feed). See also „9.2 Display messages“,
page 34.
green: <off>
red: <on/off>
yellow: <on>
General error condition.
Solar inverter is not connected to the grid.
No power is delivered. See also „9.2 Display
messages“, page 34.
green: <on/off>
red: <on/off>
yellow: <ashes>
Warning message.
You can carry on using the solar inverter.
See also „9.2 Display messages“,
page 34.
8. Operating concept
8.1 The display
The display on the device indicates varied information. The enter keys are used for the
adjustment of the device and for the retrieval of information. The indicated data can
deviate with a tolerance of up to 5 %.
ESC
(A) (B) (C) (D)
Key (A), ESC: To switch from the menu
items to the main menu and to exit each
sub-menu.
Key (B) and (C): For scrolling in the individ-
ual menu items and/or carrying out adjust-
ments in the setup menu.
Key (D), ENTER: ENTER key for changing
into the menu levels and for input acknow-
ledgement in the setup menu.