Delta SOLIVIA 5.0 Installation Manual Page 34

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 33
34 Operation and installation manual SOLIVIA 5.0 AP G3 TR
LED STATUS
DISPLAY
MESSAGE
CAUSE ELIMINATION
green: <on>
red: <off>
yellow: <ashes>
Varistor
warning
Internal varistor at the DC
input is defective.
Although you can, in theory, carry
on using the solar inverter, the
varistors should be replaced at
the earliest opportunity. This will
involve returning the device.
green: <off>
red: <off>
yellow: <on>
Block
selection
Enter keys on the display
are locked, if there is
no input entry within 5
minutes.
To unlock the enter keys, you need
to switch off the DC voltage and
then switch it on again.
NOTE
Please follow the instructions above before contacting your service
technician!
10. Technical data
INPUT (DC) AUSTRALIA INDIA
Max. recommended PV power 6000 W
P
Nominal power 5500 W
Voltage range 125 ... 540 V
Full power MPP range 150 ... 450 V
Nominal current 17.2 A
Max. current 32 A
OUTPUT (AC) AUSTRALIA INDIA
Max. power 5240 W
1), 2)
Nominal power 5000 W
2)
Voltage range 210 ... 264 V 184 ... 264.5 V
Max. current 27.2 A
Nominal current 22 A
Nominal frequency 50 Hz
Frequency range 48 ... 52 Hz 47.3 ... 52.7 Hz
Power factor > 0.99 @ nominal power
Total harmonic distortion THD) < 4 % @ nominal power
Page view 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 47 48

Comments to this Manuals

No comments