Delta 36-841 User Manual Page 4

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 3
4
POWER CONNECTIONS
A separate electrical circuit should be used for your machines. This circuit should not be less than #12 wire and should
be protected with a 20 Amp time lag fuse. If an extension cord is used, use only 3-wire extension cords which have 3-
prong grounding type plugs and matching receptacle which will accept the machine’s plug. Before connecting the
motor to the power line, make sure the switch is in the “OFF” position and be sure that the electric current is of the
same characteristics as indicated on the machine. All line connections should make good contact. Running on low
voltage will damage the motor.
WARNING: DO NOT EXPOSE THE MACHINE TO RAIN OR OPERATE THE MACHINE IN DAMP LOCATIONS.
MOTOR SPECIFICATIONS
Your machine is wired for 230 volt, 60 HZ alternating current. Before connecting the machine to the power source,
make sure the switch is in the “OFF” position.
GROUNDING INSTRUCTIONS
WARNING: THIS MACHINE MUST BE GROUNDED WHILE IN USE TO PROTECT THE OPERATOR FROM
ELECTRIC SHOCK.
2. Grounded, cord-connected machines intended for
use on a supply circuit having a nominal rating between
150 - 250 volts, inclusive:
This machine is intended for use on a circuit that has an
outlet that looks like the one illustrated in Fig. C. The
machine has a grounding plug that looks like the plug
illustrated in Fig. C. Make sure the machine is connected
to an outlet having the same configuration as the plug.
No adapter is available or should be used with this
machine. If the machine must be reconnected for use on
a different type of electric circuit, the reconnection
should be made by qualified service personnel; and after
reconnection, the machine should comply with all local
codes and ordinances.
WARNING: IN ALL CASES, MAKE SURE THE
RECEPTACLE IN QUESTION IS PROPERLY
GROUNDED. IF YOU ARE NOT SURE HAVE A QUALIFIED
ELECTRICIAN CHECK THE RECEPTACLE. NEVER
REMOVE GROUNDING PRONG FROM POWER PLUG.
NOTE: In Canada, the use of a temporary adapter is not
permitted by the Canadian Electric Code.
1. All grounded, cord-connected machines:
In the event of a malfunction or breakdown, grounding
provides a path of least resistance for electric current to
reduce the risk of electric shock. This machine is
equipped with an electric cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into a matching outlet that is properly installed
and grounded in accordance with all local codes and
ordinances.
Do not modify the plug provided - if it will not fit the outlet,
have the proper outlet installed by a qualified electrician.
Improper connection of the equipment-grounding
conductor can result in risk of electric shock. The
conductor with insulation having an outer surface that is
green with or without yellow stripes is the equipment-
grounding conductor. If repair or replacement of the
electric cord or plug is necessary, do not connect the
equipment-grounding conductor to a live terminal.
Check with a qualified electrician or service personnel if
the grounding instructions are not completely understood,
or if in doubt as to whether the machine is properly
grounded.
Use only 3-wire extension cords that have 3-prong
grounding type plugs and matching 3-conductor
receptacles that accept the machine’s plug, as shown in
Fig. C.
Repair or replace damaged or worn cord immediately.
Fig. C
CURRENT CARRYING
PRONGS
GROUNDED OUTLET BOX
GROUND
PRONG
240
VOLT
Page view 3
1 2 3 4 5 6 7 8 9 ... 39 40

Comments to this Manuals

No comments