Delta MCS-1800 Specifications Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 66
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
NEW!
925
POWER MONITORING & PROTECTION
POWER MONITORING & PROTECTION
16
WE MAKE IT EASY.
kele.com 888-397-5353 USA
Drawn to Scale
6.1 (15.5)
3.35
(8.5)
in
(cm)
1.50 (3.8) High
Ø
0.386 (1.0)
Ø
0.200 (0.5)
5.375 (13.66)
3.35 (8.5 )
WATTNODE AC POWER METER
WNC SERIES
Supply Voltage 120 to 600VAC
CT Input 0.333V nominal, 3V maximum
Operating Temperature -22°F to 131°F (-30°C to 55°C)
Operating Humidity 5 to 90% RH up to 104°F (40°C)
Dimensions 6.1" x 3.35" x 1.5"
(15.5 x 8.5 x 3.8 cm)
Weight 11oz.
RoHS Statement Ye s
Warranty 5 Years
Communication Protocol
BACnet MS/TP (RS-485)
Modbus RTU
LonWorks Network Variables (SNVTs)
Meets ARRA or BAA Ye s
Signal LEDs Diagnostic LEDs Provide per-phase
indication of power (green flashing)
and negative power (red flashing)
on BACnet, Modbus and Pulse
models only
Approvals CE, UL & cUL File #312220 FCC
Class B, EN 55022 Class B
Additional Specifications
Assembled in the USA
DESCRIPTION
WNC Series of AC Power measurement meters are available
in pulse output or will support several communication
protocol outputs. True power, kWh reactive power, VARs,
power factor, and indivitdual phase measurements.
Diagnostic LEDs provide a per-phase indication of power
(green flashing) and negative power (red flashing) to help
troubleshoot connection problems such as swapped CT's
or excessive live voltage. The meters use the safe Ct's
producing 0.333 VAC at rated current. They have a small
form factor for easy installation inside most electrical panels
with pluggable screw terminals for easy wiring. Power
Related Measurements - 50+ for BACnet and Modbus; 27+
for LonWorks.
FEATURES
BACnet, Modbus, Lonworks or Pulse
1 to 3 Phase 120VAC to 600VAC
0.5% nominal accuracy (see manual for details)
Euroblock style pluggable screw terminal blocks
Line powered
Uses safe current transformers; 0.333V output
Bidirectional
DIMENSIONS
SPECIFICATIONS
WNC Series
WIRING
Ground
WHITE
BLACK
Ø
B CT
Ø
C CT
Ø
A CT
Ø
B
Ø
C
N
Ø
A
Common
B+, D1, RxD+/TxD+
EIA-485
PC or BACnet Host
A−, D0, RxD−/TxD
Status
Status
Status
X
C
B
+
A
-
PT/SM
Com
WNC-
WNC-
W
ATT
N
ODE
®
BAC
NET
-BN
-BN
Phase A
Neutral
Phase B
WHITE
BLACK
120 VAC
240 VAC
120 VAC
LINE
LOAD
Shorting
Jumper
Source
Faces
Current
Transformers
3Y-208
3D-240
Ground
WHITE
BLACK
ØB CT
Ø
C CT
Ø
A CT
ØB
Ø
C
N
ØA
Common
B+, D1, RxD+/TxD+
EIA-485
PC or BACnet Host
A−, D0, RxD−/TxD
Status
Status
Status
X
C
B
+
A
-
PT/SM
Com
WNC-
WATTNODE
®
BACNET
-BN
Phase A
Phase B
WHITE
BLACK
208-240 VAC
LINE
LOAD
Shorting
Jumper
Source
Faces
Current
Transformers
3D-240
Single Phase Three-Wire, Mid-Point Neutral Wire
Single Phase Two-Wire without Neutral
March 2014
Page view 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 65 66

Comments to this Manuals