POWER MONITORING & PROTECTION
POWER MONITORING & PROTECTION
16
WE MAKE IT EASY.
kele.com 888-397-5353 USA
EnGenius™ Patent Pending
INTELLIGENT POWER MONITOR
ENGENIUS
TM
- PATENT PENDING
Supply Voltage 24 VAC ± 10% 60Hz
Supply Current 250 mA maximum
Monitored Voltage
Line to Line 120 to 600 VAC
Line to Line with
potential transformer
601 to 32000 VAC
Monitored Current 5 to 6000A using current
transformers
System Type 2-Wire Single Phase
3-Wire Single Phase
4-Wire Wye
3-Wire Delta
4-Wire Delta
Communication
Data Port Serial interface to EnGenius™
Desktop Software
OPTIONAL Communications
(not field installable) BACnet MS/TP
Lonworks
Modbus RTU
N2
Analog Output 1 Output
Type 4-20 mA (loop powered)
Accuracy 0.5% full scale
Maximum Loop
Supply Voltage 30 VDC
Maximum Impedance 850 @ 24 VDC
Digital Output 2 Outputs
Type Optically isolated solid state
FET switch
Rated Voltage 28 VAC/40 VDC maximum
Rated Current 00 mA maximum
Operating Temperature -22° to 158°F (-30° to 70°C)
Operating Humidity 0 to 95% (non-condensing)
Enclosure NEMA 4, UL94 rated 5VA
Dimensions 6.5” x 6.5” x 4”
(16.5 x 16.5 x 10.1 cm)
Weight 3.1 lb (1.4 kg)
Approvals ETL, CE File #4004284
RoHS Statement Ye s
Warranty 1 year
DESCRIPTION
The EnGenius™ is a two processor based power monitoring
device that monitors and records numerous power system
parameters. The EnGenius™ continuously measures
voltage and current to calculate and display over 57 values.
120 to 600V can be monitored without the need of potential
transformers. 601 to 32000 V can be monitored with the use
of potential transformers. All scaling calculations are handled
by the meter.
The Engenius™ comes standard in a NEMA 4 rated
enclosure ready to be mounted. A data port is provided
on the front interface for easy setup and trend retrieval
via EnGenius™ desktop software. Built for the future, the
EnGenius™ allows for feature upgrades through the data
port.
FEATURES
NEMA 4 enclosure standard
KWH Accuracy class 0.5% ANSI C12.20 For meter alone with
unmatched CT's OR for Meter-CT set with factory calibrated
matched CT's
Data port for setup and trend retrieval
Measure voltages up to 32000 VAC (*voltages over 600VAC
require the use of a potential transformer, not included)
Supports 0.333V safe CTs and 5 AMP CTs (must use optional
5 AMP adapter board)
Supports 1V and 2 V CT's (must use ENG-2VT/1V-ADPTR)
BACnet MSTP, Lonworks, N2 and Modbus RTU available
Password protected configuration
Powered by separate 24 VAC supply
On board data logging
Auto configuration
Upgradable firmware through data port
Bidirectional power measurement
CSI approved
SPECIFICATIONS
Parameters that can assigned to 4-20 mA output:
Total Positive KW
Total Bi-directional KW (12 mA = 0 KW)
Total Sliding Window KW (user configured, 5 to 60 min.)
Peak Sliding Window KW
Total KVA
Total PF
Average System Volts
Average System Amps
Parameters that can be assigned to Digital Outputs:
Positive KWH pulse
Negative KWH pulse
Low volts - alarm
Unbalanced volts - alarm
Low or unbalanced volts - alarm
PARAMETERS