Delta MCS-1800 Specifications Page 32

  • Download
  • Add to my manuals
  • Print
  • Page
    / 66
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 31
NEW!
POWER MONITORING & PROTECTION
942
NEW!
POWER MONITORING & PROTECTION
16
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.
kele.com888-397-5353 USA
A/CR-DC-5A A/CR-DC-12A A/CR-12DC-12A
Relay Type Contact Rating Relay Type Contact Rating Relay Type Contact Rating
SPDT 5A @ 250 VAC General Use SPDT 12A @ 250 VAC General Use SPDT 12A @ 250 VAC General Use
Coil Voltage
5A @ 125 VAC Resistive
Coil Voltage
12A @ 125 VAC Resistive
Coil Voltage
12A @ 250 VAC Resistive
23-31.2 VDC 5A @ 30 VAC Resistive 20-31.2 VDC 12A @ 30 VAC Resistive 10-15.6 VDC 12A @ 30 VDC Resistive
Coil Current
1/4HP, 120/250/277 VAC
Coil Current
1/2HP, 120/250/480 VAC-NC
Coil Current
1/2HP, 120/240/480 VAC-NC
15mA @ 24 VDC C 150 Pilot Duty 16mA @ 24 VDC A300 Pilot Duty 30mA @ 24 VDC A300 Pilot Duty
A/CR-24AC-10A A/CR-115AC-8A A/CR-230AC-8A
Relay Type Contact Rating Relay Type Contact Rating Relay Type Contact Rating
SPDT 10A @ 250 VAC General Use SPDT 8A @ 250 VAC General Use SPDT 8A @ 250 VAC General Use
Coil Voltage
10A @ 250 VAC Resistive
Coil Voltage
8A @ 250 VAC Resistive
Coil Voltage
8A @ 125 VAC Resistive
16-25.4 VAC 10A @ 30 VAC Resistive 80-132 VAC 8A @ 30 VAC Resistive 165-264 VAC 8A @ 30 VAC Resistive
Coil Current
1HP, 120/240/480 VAC-NO
Coil Current
1HP, 120/240/480 VAC-NO
Coil Current
1HP, 120/240/480 VAC-NO
28mA @ 24 VAC 1/2HP, 120/240/480 VAC-NO 10mA @ 115 VAC 1/2HP, 120/240/480 VAC-NC 5mA @ 230 VDC 1/2HP, 120/240/480 VAC-NC
A300 Pilot Duty A300 Pilot Duty A300 Pilot Duty
ACI CURRENT-OPERATED SWITCHES
A/ACS, A/ASCS, A/CS, A/SCS, A/CR SERIES
Supply Voltage Induced from monitored conductor
Frequency 40 Hz to 1 kHz
Outputs
Normally Open 0.3A @ 200 VAC/VDC
Normally Closed 0.15A @ 300 VAC/VDC
Isolation Rating 1270 VAC
Insulation 600 VAC
LED Indication
Adjustable Red = Above trip point
Green = Below trip point
Fixed Red LED only
Deadband 10% Setpoint
Operating Temperature 5° to 104°F (-15° to 40°C)
Operating Humidity 0 to 95% RH,(non-condensing)
Mounting DIN rail (35 mm), screw
Window Size 0.75" (1.9 cm), accepts up to 350
MCM cables
Weight 0.21 lb (0.1 kg)
Approvals UL and cUL listed, file #E309723 and
#E179139 CE
RoHS Statement Ye s
Warranty 5 years, limited
DESCRIPTION
The ACI current switches are solid-state devices that
operate when the sensed AC current level exceeds a fixed
or adjustable trip point. The A/CS Series is solid-core with a
fixed trip point. The A/SCS Series is split-core with a fixed
trip point. The A/ACS Series is solid-core with adjustable
trip point. The A/ASCS Series is split-core with adjustable
trip point. All models monitor either a 0-200 or 0-250 amp
current flow in the wire and are available in normally-open or
normally-closed configurations. The A/CR Series command
relay brings control to monitoring applications.
FEATURES
Available in solid or split-core
Fixed or adjustable trip points
Switches AC or DC circuits
Status LED's
Integral DIN rail mount
Powered by monitored line
Enclosure rated UL94-5VB
Pilot duty rated (A/CR Series)
SPECIFICATIONS
RELAY SPECIFICATIONS (COMMAND RELAY)
A/CR-D-12A
A/CS, A/ACS
A/SCS, A/ASCS
March 2014
Page view 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 65 66

Comments to this Manuals

No comments