Delta MCS-1800 Specifications Page 49

  • Download
  • Add to my manuals
  • Print
  • Page
    / 66
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 48
NEW!
959
POWER MONITORING & PROTECTION
POWER MONITORING & PROTECTION
16
WE MAKE IT EASY.
kele.com 888-397-5353 USA
ORDERING INFORMATION
MOTORSAVER™ THREE-PHASE VOLTAGE MONITOR
355 SERIES
Supply Watts 6W maximum
Frequency 50*/60 Hz
Contact Rating SPDT, pilot duty 470 VA @ 600
VAC (400 or 600V range) General-
purpose 10A @ 240 VAC (200V
range) 1hp @ 240 VAC (200V range)
Transient Protection 2500V for 10 ms
Line Voltage Monitored 190-240, 380-480, or 575-600 VAC
Low Voltage Trip 90% of setpoint (±1%)
Low Voltage Reset 93% of setpoint (±1%)
Reset Delay Time after Fault
Manual or 2-300 seconds
Reset Delay Time after Power Loss
Manual or 2-300 seconds
Trip Delay Time High Voltage
2-30 seconds, adjustable
Trip Delay Time Low Voltage
2-30 seconds, adjustable
Trip Delay Time Phase Fault
0.5 seconds
Trip Delay Time Unbalance
2-30 seconds, adjustable
Voltage Unbalance Reset
Trip setting minus 1%
Voltage Unbalance Trip 2% to 8%, adjustable
Dimensions 2.9”H x 5.25”W x 2.9”D
(7.4 x 13.3 x 7.4 cm)
Weight 1.0 lb (0.45 kg)
Approvals UL and cUL listed, File #E68520
Warranty 5 years
DESCRIPTION
The MotorSaver355 Series Three-Phase Voltage
Monitors are designed to protect three-phase motors
regardless of size. The 355-200 model monitors 190-240
VAC input voltages, the 355-400 model monitors 380-480
VAC input voltages, and the 355-600 model monitors 575-
600 VAC input voltages. The unique microprocessor-based
voltage and phase-sensing circuit constantly monitors the
three-phase voltages to detect harmful power line conditions,
including single phasing, low-voltage, phase reversal, voltage
unbalance, and high voltage. When a harmful condition
is detected, the 355 Series output relays are deactivated
after an adjustable trip-delay time period. The output relay
reactivates after power line conditions return to an acceptable
level for an adjustable restart delay time. The trip and reset
delays prevent nuisance tripping due to rapidly fluctuating
power line conditions.
FEATURES
Protection of three-phase motors from loss of any
phase, low-voltage, phase reversal, voltage unbalance,
and high voltage
Adjustable restart delay
Adjustable trip delay
Adjustable voltage-unbalance trip point
Four diagnostic LEDs show overvoltage, undervoltage,
voltage unbalance, reverse-phase and normal
conditions
UL and ULC listed
Single-phase condition detection regardless of
regenerated voltages
OL
OL
OL
OL
Motor
L1
L1
L2
L3
L2 L3
M
Start
M
M
M
M
Stop
Hand
Auto Pilot
Off
Control
Voltage
355 Series
WIRING
MODEL DESCRIPTION
355-200 Three-phase voltage monitor, 190-240 VAC
355-400 Three-phase voltage monitor, 380-480 VAC
355-600 Three-phase voltage monitor, 575-600 VAC
SPECIFICATIONS
355-400
Shown de-energized
* 50 Hz will increase all delay times by 20%.
March 2014
Page view 48
1 2 ... 44 45 46 47 48 49 50 51 52 53 54 ... 65 66

Comments to this Manuals