Delta MCS-1800 Specifications Page 56

  • Download
  • Add to my manuals
  • Print
  • Page
    / 66
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 55
NEW!
POWER MONITORING & PROTECTION
966
NEW!
POWER MONITORING & PROTECTION
16
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.
kele.com888-397-5353 USA
ORDERING INFORMATION
MODEL DESCRIPTION
PC642C Dual-pair (four-wire) surge protector, base mount (PCB1B required)
DRS Single-pair (two-wire) surge protector, DIN rail mount
-008 Clamp voltage, 8V
-015 Clamp voltage, 15V
-030 Clamp voltage, 30V
-036 Clamp voltage, 36V
-LC Low capacitance option (PC642C only)
PCB1B Mounting/connector base for PC642C
DATA LINE SURGE PROTECTOR
DRS, PC642C SERIES
Voltage Clamp (±10%) 8, 15, 30, or 36V
Response Time <1 ns
Peak Surge Current <10 kA (8 x 20 µs)
Life Expectancy >100 occurrences @ 2000A,
8 x 20 µs
Series Resistance 5Ω nominal
Operating Temperature -40° to 185°F (-40° to 85°C)
Dimensions
PC642C, PCB1B 2.5"H x 1.0"W x 2.0"D
(6.1 x 2.5 x 5.1 cm)
DRS 2.95"H x 0.8"W x 2.35"D
(7.5 x 2.0 x 6.0 cm)
Capacitance 1500 pF; PC642 w/ LC option: 50 pF
Operational Current Maximum 150 mA @ clamp voltage
Protector
Primary Three-element gas tube (GDT)
Secondary Rugged solid-state avalanche diode
(SAD)
Third Positive temp coefficient device
(PTC)
Approvals UL497B, File #E175287
Weight 0.06 lb (0.03 kg)
Warranty 1 year
DESCRIPTION
The Model PC642C Series surge suppressor is a dual-pair
(four wire) and the DRS Series is a single pair (two-wire)
DIN rail mount module implementing three-stage hybrid
technology. These modules protect against over-voltage
transients with gas tubes and silicon avalanche components.
In addition, sneak and fault currents are mitigated with
automatic resetting fuses (PTCs). The PTCs increase
resistance several orders of magnitude when over currents
are present and return to normal when over-currents are
removed. The ability to self-restore in this manner significantly
increases suppressor performance and survivability.
FEATURES
Lightning protection for low voltage signal lines
Three-stage protection
Plug-in and DIN rail mount modules
Automatic recovery
Nanosecond response time
Ground
Equipment
Side
Field Side
DRS
Shield
Line
Line
WIRING
SPECIFICATIONS
If a shield is used, then
ground at one end only.
Keying Pin
PC642C on PCB1B
10
8
6
4
2
9
7
5
3
1
Pin 1 or 10 grounded
to local
building-
appro
ved ground
Do not install
your
ow
n ground rod.
Unprotected
Pair 1
Unprotected
Pair 2
Protected
Pair 1
Protected
Pair 2
Data Line In
Data Line Out
Field Side
Electronics Side
DRS
PC642C
PCB1B
March 2014
Page view 55
1 2 ... 51 52 53 54 55 56 57 58 59 60 61 ... 65 66

Comments to this Manuals