Delta MCS-1800 Specifications Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 66
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
NEW!
POWER MONITORING & PROTECTION
918
NEW!
POWER MONITORING & PROTECTION
16
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.
kele.com888-397-5353 USA
ENG-485
Mounting Holes
IN1IN2
1
2
GND
RX
TX
GND
RS-485 Communications
Terminals
RS-485 Reference Conductor (if used)
RS-485 Twisted Pair ‘AConductor
RS-485 twisted pair is polarity sensitive.
If unable to communicate, try reversing the ‘Aand ‘Bconductors.
Optional
External Status or
Pulse Count contacts
Ribbon Cable
Plugs Into EnGenius Main Board
(Disconnect 24 VAC power before
plugging or unplugging)
Module Status LED
Receive Data,
Transmit Data
Statuts LEDs
RS-485 Twisted Pair ‘BConductor
A(+)
B(–)
ORDERING INFORMATION
COMMUNICATION MODULES FOR ENGENIUS™
ENG-485, PT-NTL-10
Communication
PT-NTL-10 LonWorks FTT-10 transceiver
ENG-485 BACNet, Modbus, N2
Connections Pluggable screw terminals
Operating Temperature
PT-NTL-10 32° to 122°F (0° to 50°C)
ENG-485 14° to 122°F (-10° to 50°C)
Operating Humidity 0-95% RH non-condensing
Dimensions
PT-NTL-10 4.5"H x 2.6"W x 1.7"D
(11.4 x 6.6 x 4.3 cm)
ENG-485 4.5"H x 2.6"W x 0.6"D
(11.4 x 6.6 x 1.5cm)
Weight
PT-NTL-10 0.7 lb (0.32kg)
ENG-485 0.1 lb (0.05 kg)
Approvals UL listed, File #E161500
PT-NTL-10 Certified to LonMark Interoperability
Guidelines v 3.1
Warranty 18 months
DESCRIPTION
The ENG-485 and PT-NTL-10 are communication modules for
EnGenius™ Intelligent Power Monitor. They read data from the
EnGenius™ main processor, format the data, and transmit it to a
network. They allow all of the power system parameters measured
by the EnGenius™ to be monitored over a single pair of wires.
The ENG-485 contains BACNET, Modbus and N2 communication
protocols. The chosen communication protocol is selected either
through the front panel display/keypad or the desktop software.
The ENG-485 features 2 contact-closure inputs for monitoing
external equipment. Each input can be configured to read
contact state (On/Off) or as a Pulse Counter to count pulses
from flow meters or other power meters. In the Pulse Counter
mode, a Clear command is available to reset the pulse count
when desired.
The PT-NTL-10 is a a dedicated Lonworks communication module.
This module does not have the 2 contact-closure inputs.
FEATURES
ENG-485 contains BACnet, Modbus & N2 communication
protocols on one board. The chosen one is selected either
through the the front panel display/keypad or through the
optional Desktop Software.
2 Contact-closure inputs
PT-NTL-10 is a dedicated Lonworks module. This protocol has
a subset of values. See data sheet for details.
PT-NTL-10
Ribbon
Cable
Status
LED
To LonWorks
FT-10 Network
Service Button
Not Polarity
Sensitive
Service LED
FTT-10
CONTROL
MODULE
FT-10 NWK
WIRING
SPECIFICATIONS
ENG-485
ENG-485 PT-NTL-10
MODEL DESCRIPTION
ENG-485 BACnet, Modbus, N2 Communication Board
PT-NTL-10 LonWorks communications module
March 2014
Page view 7